Page 7
COMMANDER SEARCHLIGHT -
INSTALLATION AND USER MANUAL
3.1 CLEANING
PANEL:
The control panel may be cleaned with a mild detergent on any parts.
SEARCHLIGHT:
Keep the searchlight and lens clean. Use only water and soft cloth to
clean the searchlight. Clean the front glass / lens only when the light is
off and has cooled down. If necessary, clean the mirror using alcohol.
Ensure that all remains of the cleaning solvent are removed. Use only
a soft cloth to clean the mirror.
3.2 LUBRICATION
The lubrication point at the bottom of the U-pieces should be greased
every two years. Use grease which is resistant to temperatures down
to –50°C.
3.3 MECHANICAL
Check all external screws on the searchlight periodically and tighten if
needed.
Control that the lamphouse moves smoothly and with low friction both
horizontally and vertically. Do not overtighten the four bolts in which
the lamphouse is hinged, as this may hinder the movement of the
searchlight.
Remove build-up of ice on and around the searchlight. The motor unit
and the lamphouse optional have both an internally mounted heater to
avoid condensation, but it is not designed for de-icing the searchlight.
3.4 ELECTRICAL
SEARCHLIGHT:
Clean and inspect the electrical connections to xenon
lamp periodically. A layer of oxidation can build up as a result of lamp
heating and cooling. Also inspect the other high current connections
for bad contacts and overheating.
4.2 ELECTRICAL INSTALLATION - CABLING
CABLING – COMMUNICATION NETWORK:
1. Use 2x twisted pair cable or 1x twisted pair + screen. Characteris-
tic impedance: 100 – 250 ohms. Suitable cables types can be cables
made for Profibus, Interbus, Ethernet, Cat5, or similar.
2. The communication network must be connected as a bus topol-
ogy, i.e. from point to point (unit to unit). No loops or star connec-
tions are allowed. ( See drawing 600A105539)
3. No end terminations are necessary.
4. Connect A to A, B to B and Ref to Ref. Ref is also called Sh on
some units.
5. The order of panels and searchlights along the bus can be freely
chosen. Tip: A drawing of the system showing the order and ad-
dresses of the units can be of great help if troubleshooting should be
necessary.
3 MAINTENANCE
4 INSTALLATION
4.1 MECHANICAL INSTALLATION
SEARCHLIGHTS PHYSICAL PLACEMENT:
Consider the end stop of the horizontal movement, the end stop is
placed at the connection box, i.e. when the light head is facing in the
same direction as the connection box. Also consider if there are sectors
which should not be illuminated.
SEARCHLIGHT MOUNTING:
The seachlight is mounted to base with 8 PCS M10 bolts. Please note
that the motorhousing is equipped with 2 pcs. Ø4 drain holes. For
these to have any draining effect, the included TEF 2650 mounting
standoff kit (part no: 5024) must be installed between the motorhous-
ing and the base where the searchlight is based (Fig. 1M). For more
details on dimensions please see drawing 600A102893 page 21 in this
manual.
Содержание TEF 2650
Страница 18: ...Page 18 COMMANDER SEARCHLIGHT INSTALLATION AND USER MANUAL 600A103633 LAMP HOUSING TEF 2650 HALOGEN ...
Страница 19: ...Page 19 COMMANDER SEARCHLIGHT INSTALLATION AND USER MANUAL 600A103633 PART LIST FOR LAMP HOUSING ...
Страница 25: ...Page 25 COMMANDER SEARCHLIGHT INSTALLATION AND USER MANUAL 600A102101 CONTROL PANELS DIMENSIONS AND CUT OUTS ...
Страница 26: ...Page 26 COMMANDER SEARCHLIGHT INSTALLATION AND USER MANUAL 600A105539 SYSTEM EXAMPLE WIRING DIAGRAM ...