Left Side Panel 

Power Switch

:

Press the power switch to (1) turn the power on. Within 10­20 seconds, as the heaters reach

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

operating temperature the tubes will begin to glow a soft orange light. Press the power switch to (0) to turn the

 

 

 

 

 

   

   

 

 

 

 

 

 

   

   

 

 

unit off. As the heaters cool off, the orange glow will slowly disappear.

 

 

It is normal for a vacuum tube equipment to run warm if used for prolonged periods. Tubes are

   

 

   

 

 

 

 

 

   

 

 

 

 

 

 

operating at much higher temperature and should not be touched for at least ten minutes after the unit

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

is turned off to prevent burns. Always place your amplifier away from children and pets to prevent

 

 

   

 

 

 

 

 

 

 

 

 

 

   

 

burns.

 

 

 

Audio signal connection jacks

 

­

 

Use these jacks to connect the audio interconnects from your 

components to the amplifier. 

 

Speaker terminals ­

Your amplifier has two output channels, the Right Output and the Left Output. Each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output channel is designed to handle one speaker. Follow the instructions outlined in the Operating Procedure

 

   

   

 

 

 

 

 

 

   

 

 

 

for the correct speaker connections.

 

 

 

TUBE REPLACEMENT

 

Your 

EOS

 

amplifier’s conservative design maximizes tube life. You can expect that your Tungsol KT120 tubes 

will last in excess of 2000 hours, while the drive 6N6P­EV tubes and 5687 preamplifier tubes should last 
approximately 3500 hours. Due to most people’s lack of desire and inability to time every listening session,, we 
strongly recommend replacing the output tubes at 20­30 months, (depending on your listening habits) and your 
signal tubes at every other power tube replacement (every 24­36 months). This will ensure that the amplifier 
always performs at its best and tube failure will not overstress other parts. 

 

Before you begin tube replacement you should make certain that the unit is turned off and disconnected from

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

the AC outlet and that the current tubes have cooled down. Allow sufficient time, 30 minutes is plenty, for the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

tubes to cool down and the internal capacitors to discharge. Before inserting a new tube, inspect the tube for

   

 

 

 

 

 

   

 

 

   

 

 

 

 

 

 

cracks and physical damage. Make sure that the pins are straight. If you need to straighten the pins, be very

 

 

 

 

 

 

 

 

 

 

   

 

   

 

 

 

 

 

careful as it may cause the glass envelope to break, causing the tube to lose the vacuum and fail as soon as the

     

 

 

 

 

   

 

 

 

   

 

 

 

 

   

   

 

amplifier is powered on, possibly damaging the amplifier as well. Also, make sure to inspect the tube sockets for

   

 

 

 

 

 

   

 

 

 

   

 

 

 

   

cracks and pin inserts. Carefully align the pins with the socket and gently insert the new tube.

Never force a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

tube into a socket.

Should you decide to buy replacement tubes from Trafomatic Audio, rest assured that they

 

   

 

 

 

   

 

 

 

 

 

 

 

 

 

 

were fully tested before the shipment. 

Only KT120 power tubes can be used. Regarding the preamplifier and drive tubes, the 6N6P and 5687 tubes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CANNOT

be replaced with other tube such as the ECC81,82, 83, or 88. No other tube types should be used as

   

 

 

 

 

   

 

 

   

 

 

 

 

 

   

   

this may cause damage to the amplifier, dasmage which is not covered by the warranty. 

We do not recommend frequent changes of the tubes, as the sockets are sensitive mechanical parts

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

and are rated for a relatively small number of insertions

.  

 

12 

 

Содержание EOS Series

Страница 1: ...1 ...

Страница 2: ...2 ...

Страница 3: ... EOS Stereo Integrated Tube Amplifier Stereo Power Tube Amplifier User s Manual http www trafomaticaudio com Rev 1 3 ...

Страница 4: ...tting Started About Your Amplifier 5 Construction and Testing 5 Packaging Unpacking 5 6 Accessories 6 Preparation for Use 6 Operating Procedures 6 Controls and Their Functions 7 Vacuum Tube Layout 8 Tube Replacement 8 9 Servicing 9 Technical Specifications 9 4 ...

Страница 5: ...source indicated on the marking label If you are not sure of the type of power supply in your home consult your product dealer or local power company 5 Grounding This product is equipped with a three prong IEC connector Always use power a cord with an adequate wire cross section and an electrical outlet that is grounded If you do not know whether the outlet is grounded consult your electrician or ...

Страница 6: ...lace anything on top your amplifier that could obstruct the airflow and cause the electron tubes to overheat and damage the amplifier Do not place your amplifier in a closed bookcase overheating could occur Ensure that there is at least 8 200mm of open space above the amplifier 3 Surface Place the unit on a flat level surface Care should be taken to prevent objects from falling on or into the unit...

Страница 7: ...omfortable space around that area when biasing the amp Give yourself a good 12 inches and this will be an easier exercise Now you re ready to switch on your amp I like to let the amp set for at least 3 minutes Once that time has passed we will begin the biasing You ll see the bias knob dead center on the top of your amp The tubes get a little hot so you ll want to use caution That s why we left th...

Страница 8: ...afety problem and result in reduced lifetime of the product Any removal of the cover will void the warranty Getting Started About Your Amplifier Your EOS amplifier was designed to provide a significant value based on a high performance to price ratio that will exceed the sonic quality of good solid state amplifiers with its musical accuracy The EOS uses four Tungsol KT120 power output tubes two 6N...

Страница 9: ...he shipment Packaging Save all the packaging in a dry place Your amplifier is a precision electronic instrument and should be properly packaged any time shipment is made Because of its weight it is highly probable that the unit will be damaged during shipment if repackaged in a box and packing other than that designed for the unit Preparation for Use Place your amplifier on a flat surface Before i...

Страница 10: ...Speaker s minus terminal should be connected to the speaker terminal marked as zero 0 and positive terminal should be connected to the terminal that corresponds to the speaker s nominal impedance 4 or 8 ohms The amplifier is optimized for these impedances Higher or lower impedances will result in higher distortion or loss of power Do not use a speaker with impedances lower than 2 ohms on either of...

Страница 11: ...ower output This can damage your speakers or ears Always take care that volume controls are in the proper position as in turned down and that you use a controllable source 4 The amplifier will be fully functional after only a couple of minutes However as it warms up over 30 minutes you may notice a slight improvement in the sound quality 5 At the end of your listening session make sure to turn the...

Страница 12: ...on your listening habits and your signal tubes at every other power tube replacement every 24 36 months This will ensure that the amplifier always performs at its best and tube failure will not overstress other parts Before you begin tube replacement you should make certain that the unit is turned off and disconnected from the AC outlet and that the current tubes have cooled down Allow sufficient ...

Страница 13: ... only minimal service to maintain its high level of performance CAUTION Lethal voltages are present inside the amplifier Do not remove the amplifier s bottom cover and do not tamper with components inside the unit even with the power turned off Servicing should be left only to authorized and trained personnel 13 ...

Страница 14: ...mplifier Input sensitivity 0 8Vef Input impedance 100 kohm S N 83 dB 1KHz 1W Output speaker impedance Speaker terminals for 4 and 8 ohms Tubes 4 x KT120 2 x 6N6P EV 2x 5687 Input Voltage 120V 60Hz or 230V 50Hz as marked on the real plate of power supply box Maximum input current 4A at 120V 2A at 230V Dimensions Width x Depth x Height 450mmx350mmx240mm Weight of amplifier 25kg Weight of power suppl...

Отзывы: