background image

TO ASSEMBLE

1.  Ensure the fuel regulator valve is off   

(turn knob  

 fully clockwise to 

-

).

2.  Make sure the seal inside the fuel 

regulator is seated properly and 
is in good working condition.

3.  Screw the fuel regulator  

4

  onto the fuel 

cartridge  

8

  in a clockwise direction, 

hand tighten only. DO NOT OVER TIGHTEN.

4.  Ensure the oxygen regulator valve is off 

(turn knob  

3

  fully clockwise to 

-

).

5.  Make sure the seal inside the oxygen 

regulator is seated properly and 
is in good working condition.

6.  Screw the oxygen regulator  

 onto the 

oxygen cartridge  

7

  in a clockwise direction, 

hand tighten only. DO NOT OVER TIGHTEN.

NOTE: It may be easier to screw the cartridges 
onto the regulators in a clockwise direction. 
Hand tighten only. DO NOT OVER TIGHTEN.
IMPORTANT: Before lighting the flame 
make sure that all connections have been 
properly made. Check that there are no 
leaks with the appropriate gas leak spray 
or a solution of soapy water. Repeat this 
operation every time a cartridge is replaced.

STAND ASSEMBLY INSTRUCTIONS

This equipment is supplied with a 
metal stand / cartridge holder. 
1.  Once you have connected the cartridges 

to the regulators, slide each cartridge into 
one side of the stand, making sure that the 
butterfly nut on the back of the stand is 
screwed onto the bolt just enough to hold 
the front metal cartridge strap in place. 

2.  Once you have both cartridges inserted 

into the stand, tighten the butterfly nut 
until it stops. Do not over tighten as you will 
damage the butterfly nut or the centre bolt. 

3.  When inserting the cartridges make sure that 

the hoses are not tangled, and the cartridges 
are put on the correct sides of the stand 
in order for the hoses not to be crossed.

3

Содержание Oxypower

Страница 1: ...eld metal without the use of oxy acetylene equipment With a total weight of less than 5kg including cylinders this kit allows you to carry out jobs similar to those performed by much heavier equipment...

Страница 2: ...en the weight of a full cartridge and of an empty one is not easily recognised The oxygen regulator is fitted with a high pressure gauge that allows you to check the contents of the oxygen cartridge A...

Страница 3: ...TANT Before lighting the flame make sure that all connections have been properly made Check that there are no leaks with the appropriate gas leak spray or a solution of soapy water Repeat this operati...

Страница 4: ...linder clockwise direction TO IGNITE It is recommended that in normal use the pressure regulator knobs are opened completely with flame adjustment controlled by the torch knobs For storage transport a...

Страница 5: ...ge fuel knob of the torch 12 by turning it anti clockwise This should then extinguish the flame all together 3 Turn both the orange 4 and blue 2 knobs at the regulators in a clockwise direction This w...

Страница 6: ...and constant pressure In addition the equipment has six flash back arrestors that ensure equipment safety Always inspect this equipment before use This includes connections hose and torch assembly If...

Страница 7: ...f protective glasses see the instructions for use provided with them Regular inspection of equipment is required to ensure correct function Many of the components used in this equipment cannot be repa...

Страница 8: ...Distributed by TradePem Idustrial Pty Ltd www tradeflame com...