Secure the Work Piece

Wherever possible secure the work piece using clamps or a vice. It is safer than using your
hand and leaves both hands free to control the air tool.

Do Not Over-reach

Do not over-reach, keep proper footing and maintain your balance at all times.

Maintain Tools with Care

Keep cutting tools sharp and clean for better and safer performance. Follow the instructions
for lubricating and changing accessories. Check the tool power cord periodically and if
damaged have it replaced by an authorized service facility. Keep handles dry, clean and free
from oil and grease. Ensure that ventilation slots are kept clean and free from dust at all times.
Blocked ventilation slots can cause overheating and damage to the motor.

Stay Alert

Watch what you are doing, use common sense, and do not operate the air tool when you
are tired or have taken medication that causes drowsiness, consumed alcohol or drugs.

General Warnings for compressors

Do not attempt to modify the compressor in any way.

The use of any tools or accessory other than those designed for use with

compressed air could result in injury to the operator.

The output pressure of the compressor should be adjusted to the design pressure

of the air tool or accessory being used.

Always check that the output of the compressor does not exceed the maximum

pressure for any attached tool or accessory.

Repairs should only be carried out by qualified persons using original spare parts.

Failure to do so may result in considerable danger to the user.

Breathable Air Warning

This compressor/pump is not equipped for, and should not be used to supply breathing
quality air for any application of air for human consumption.

Overload protection

. This compressor is fitted with an overload protection device. In the

event that the motor becomes too hot, a thermal protection device will cut the mains supply
to the motor. When the motor temperature returns to normal the mains supply will be
restored automatically.

Extension Cords and Reels

In general, it is not recommended to use an extension lead. A longer air line is recommended
as voltage drop on extension leads may lead to motor damage and will void warranty. If an
extension cord must be used, for lengths up to 5 metres, an approved 15 amp rated cord must
be used.

Содержание MCFRC100

Страница 1: ...DIRECT DRIVE COMPRESSORS MCFRC100 102A 103 108 109 107 113 MCFRC100 108 MCFRC102A 109 MCFRC103 MCFRC107 MCFRC113...

Страница 2: ...ool to the Retailer is required together with the proof of purchase should be included with the returned product This warranty does not apply to damage that is determined to be from repairs made or at...

Страница 3: ...or fire from combustible materials flammable liquids e g paint varnish petrol etc or flammable gases and dust of an explosive nature Guard Against Electric Shock Do not expose your compressor to rain...

Страница 4: ...than those designed for use with compressed air could result in injury to the operator The output pressure of the compressor should be adjusted to the design pressure of the air tool or accessory bei...

Страница 5: ...at is damaged should be properly repaired or replaced by an authorized service centre Disconnect Compressor Ensure that the compressor is disconnected from the mains supply and the tank is empty when...

Страница 6: ...sor 2 Pressure Switch 3 Outlet Valve 4 Pressure Regulator 5 Pressure Gauge 6 Non Return Valve 7 Drain Cock 8 Wheel 9 Discharge Pipe 10 Air Tank 11 Safety Valve 12 Fan Cover Note Fittings may differ fr...

Страница 7: ...topper 3 Air Filter 4 Oil Breather plug 5 A bottle of oil Fit the wheels to the unit using the axle kit provided and insert the rubber stopper into the spigot on the bottom of the tank Fit the air fil...

Страница 8: ...il from the oil breather hole until the oil reaches the red mark on the sight glass Check that the small hole in the top of the breather pipe is clear and then insert it into the oil filler hole NOTE...

Страница 9: ...the mains Start the compressor by pulling on the red knob Check for air leaks Note Output fittings may differ from those shown Warning Use the red knob to turn the unit on and off not the mains switc...

Страница 10: ...that during use of the compressor the motor will cycle start and stop under the influence of the rising or falling pressure in the tank and the motor will start without any warning The maximum and min...

Страница 11: ...Weekly 1 Remove air filter element and clean or replace as required Monthly 1 Inspect non return valve clean or replace as required Caution ensure that air the tank is empty for this operation 2 Manu...

Страница 12: ...c and replace if necessary Excessive vibration or abnormal noise Connecting part loose Foreign body got into main compressor Piston knocking valve seat Moving parts seriously worn Check and retighten...

Страница 13: ......

Страница 14: ...4 Screw ST3 4 16 2 13B Piston Pin for MCFRC102A 109 103 1 45 Handle Grip 1 14 Circlip 12 2 46 One way valve 1 15A Connecting rod for MCFRC100 108 1 47 Bolt M8 25 4 15B Connecting rod for MCFRC102A 109...

Страница 15: ......

Страница 16: ...ut M8 PC 1 15 Piston PC 1 50 Air Filter PC 1 16 Hole Clip 12 PC 2 51 Handel Grip PC 1 17 Piston Pin PC 1 52 Discharge Pipe SET 1 18 Connect Rod PC 1 53 Bolt M8 30 PC 4 19 Oil Breather PC 1 54 Nut M8 P...

Страница 17: ......

Страница 18: ...ector A PC 1 16 connecting rod PC 2 52 Tree way connector B PC 1 17 breath pip SET 1 53 Leak valve PC 1 18 crankcase cover PC 1 54 right angle connector PC 1 19 oil leveler SET 1 55 Discharge Pipe PC...

Страница 19: ...Distributed by L G Tool Machinery Distributors Limited 6 Kyalami Rd Westmead 3610 P O Box 15313 Westmead 3608 Telephone 031 7176800 Fax 031 7176868...

Отзывы: