Rev.: 10/13 – NA
Installation and maintenance manual
Tractelift
®
Type II
Page 17 of 24
Copyright 2013,
Tractel
®
P4795 NA
all rights reserved.
d) Once the control panel is in place, lock the panel
pin in place by twisting the pin. (Fig. 23 & 24).
e) Connect the two control cables together,
connection is by male and female connectors.
Both connectors have a positive fitting (D)
connections and can only be connected in one
alignment only
(Fig. 25 & 26)
. The connector
should tighten completely.
(Fig. 28 item E)
5.5.1 Disconnecting the Control Panel
a) Disconnect the power supply and the control cables
b) Disengage the panel pin and slide the control box
up off the mounting plate.
c) Place the control panel back into the carrying con-
tainer
Fig. 24 - LOCKED
Fig. 23 - OPEN
5.5 Installing the optional detachable control
panel
a) With the lower pulley and motor installed the unit is
ready for the removable control panel (Fig. 20)
b) Remove the control panel from the container (Fig. 21)
c) Slide the control panel (A) onto the mounting plate
(B) (Fig. 20, 21 & 22).
Note: When connecting the control panel, be careful
not to damage the radio antenna (C) (Fig. 22)
Fig. 20
Fig. 21
A
B
A
Fig. 22
B
C