23
12. PRODUCT MARKING
All of the indicators and labels placed on the product by the manufacturer must be kept clearly readable.
Should they be lost or damaged, replace these indicators and labels before continuing to use the
appliance. Tractel
®
can provide new labelling on request.
Trouble
Possible causes
Solutions
Dead sensor batteries
Sensor switched off or
switched to take standby
mode.
Sensor too far from display
unit.
Network conflict
Replace batteries.
Switch off display unit, switch
on sensor, switch on display
unit.
Bring appliances closer
together.
Check network configuration
.
Sensor subject to compression
or torsion.
Negative imbalance of gauge
bridge.
Eliminate compression stress
on sensor.
Contact the after-sales service.
Switch on a Master display unit
on a site where several LLX1
are already operating.
Select a other channel
(see § 7).
Ineffective display
Malfunction of the display.
Keep the ON/OFF key pressed
during 10 sec.
Reboot both load cell and
display.
Marking display
Marking battery
charger
GB