background image

 

 

Page 

12

 of 

14

 

 

WARRANTY

 

THE TRACS WARRANTY 

American Quality Manufacturing in conjunction with TRACS Manufacturing, sole 
manufacturer of the TRACS Air Purifiers, warrants that for the life-time of this product

,

 

the frame will be free from manufacturing defects and will be replaced or repaired at our 
cost.  During the first 30 days following receipt of our air purifier, you are entitled to a 
100% refund for any reason.  

For a period of 5 years after accepting delivery

, the mechanical and electrical 

components of the TRACS air purifiers, will be under warranty.  AQM, at its option, will 
repair or replace the product or any component of the product found to have 
manufacturing defects during the warranty period. If the product is no longer available, 
replacement may be made with a similar product of equal or greater value. 

This warranty is non-transferable

 and is valid from the date of the original purchase. 

Proof-of-purchase is required to obtain warranty performance; however, your name and 
address is recorded by this website with your purchase and we should have a record of 
the sale. 

This warranty does not cover consequential damages and/or damages resulting from 
negligent use or misuse of the product by failure to store, maintain and/or use the 
product in accordance with directions otherwise. In addition, disassembly, repair or 
modification by anyone other than TRACS, acts of God, such as fire, flood, hurricanes, 
and tornadoes will not be covered. 

 

HOW WE CAN OFFER A LIFE-TIME WARRANTY ON OUR FRAME 

Our construction technique gives us the utmost confidence in our product line and the 
ability to offer a LIFETIME GUARANTEE on our air purification systems.  Both our 
portable and ceiling mounted air purifiers are made using this same welded-steel 
technique.   Once the entire frame has been welded together by highly skilled 
craftsman, the welds are sanded down for a smooth finish.  The TRACS air purifiers are 
then painted with a baked-on powder-coated finish and assembled by hand.  This is 
American workmanship at its finest and what Made in the USA truly means. 

   

Содержание 250-P-UVC

Страница 1: ...Page 1 of 14 OWNER S MANUAL TRACS Portable UV C Air Purifier Model TRACS 250 P UVC Made in the USA...

Страница 2: ...ow to use 5 WARNINGS UV C light dangers 6 Wear masks gloves 6 Unplug for maintenance 6 Contamination is present 6 SET UP OPERATION Unpacking 7 Remove the back panel 7 Install UV Lamps 7 Remove plastic...

Страница 3: ...arbon pre filters 9 HEPA filter 9 UV C lamps 10 Clean inspect 10 TROUBLESHOOTING Will not start 11 Control Panel Lights 11 WARRANTY 30 Day Money Back 12 5 Year Mechanical 12 Life time Frame 13 Made in...

Страница 4: ...TRACS changes the way you live and breathe in your home or office In order to ensure optimizing the unit s effectiveness and safe use please read this Owner s Manual in its entirety before installing...

Страница 5: ...l cycle all the air in a room up to 1000 square feet every 20 minutes Therefore place the unit in the middle of the room where people are present As people speak their airborne droplets are floating a...

Страница 6: ...can view indirect UV light but you should not stare directly into the UV lamps TRACS is fitted with a recessed electrical kill switch that turns the unit off when the back panel is removed to ensure...

Страница 7: ...uld never defeat the interlock to energize the system with the cover removed INSTALL THE UV C LAMPS Two reflective UV shields located below the prefilter basket cover the UV lamps in order to increase...

Страница 8: ...m Plug in and verify proper fan operation and the UV light indicators on the control panel are lit VERIFY PROPER OPERATION Plug the air cleaner in and verify proper operation of unit by turning fan co...

Страница 9: ...ear masks and gloves when replacing used HEPA filters Have a plastic bag ready for immediate disposal TRACS is equipped with a locking system to ensure air will not bypass around the HEPA filter In th...

Страница 10: ...ves gently insert the replacement lamps into the lamp holders until they snap into place It may be beneficial to wear protective gloves during this procedure as gloves will ensure oils from your skin...

Страница 11: ...u may also try the back panel access door emergency cutoff switch It is located underneath the unit Please do not bypass this switch with the access panel removed If this switch is not activated the u...

Страница 12: ...ired to obtain warranty performance however your name and address is recorded by this website with your purchase and we should have a record of the sale This warranty does not cover consequential dama...

Страница 13: ...resentation or description with respect to this other than as set forth below The warranty and remedies set forth below are exclusive and in lieu of all others oral or written expressed or implied No...

Страница 14: ...ad 5 REINSTALL THE BACK PANEL Reinstall the back access panel 6 VERIFY PROPER OPERATION Plug the TRACS commercial portable air cleaner in and verify proper operation of unit by turning fan control kno...

Отзывы: