Trackunit 4520202 Скачать руководство пользователя страница 19

TU600A 

 

 

 
 

Trackunit TU600A, Technical Manual v1.1, June 2021  

Page 19 

Installation of the digital output 

According to the E1 certificate of the TU600A unit, it is prohibited under any circumstances to use 
this output to control any equipment that may influence the safety of the construction machinery 
and earth moving machines/vehicle operation and driving. The output must only be used to control 
comfort equipment. 
 
The example shows a 
12V relay function with a 
12V DC supply voltage. It 
is also possible to use a 
24V relay with a 24V DC 
supply voltage etc. The 
current consumption of 
the relay must not exceed 
200 mA (DC current) and 
the relay contacts must 
be specified to withstand 
the load that needs to be 
controlled. 

 
 
 
 
 
 
 
 
 
 
 
 
 

NOTE:

 

The output can only handle DC and 

not

 AC voltage. It is necessary to only use a DC 

power supply for the relay.

 

 

 

Important!

  

The power supply connected to the TU600A (GSM/LTE M1/NB IoT)/GPS unit 
and the supply voltage for the relay mounted on the digital output must have a 
common ground connection.

  

 

One application example for the “Usable contact function controlled by the TU600A” signals shown 
in the figure above could be a “Start Relay”, blocking function, for preventing unauthorized use of 
the moving machinery and construction machine or vehicle outside normal working hours etc. 

 

Содержание 4520202

Страница 1: ...TU600A TU600A Technical Manual Version 1 1 June 2021...

Страница 2: ...fety Information 11 Automatic battery safety during operation 11 Delivered standard content 12 Ready to Use No Custom Programming Required 12 Cost effective Universally Available Communications 12 Use...

Страница 3: ...C certification statements 26 Automotive off road vehicles machinery etc 27 Statement for ISO 13849 1 safety 27 EU regulations and directives 28 CE marking 29 PTCRB certification for interoperability...

Страница 4: ...or as otherwise instructed by Trackunit Warranty Exclusions and Disclaimers The foregoing Product Limited Warranty shall only apply in the event and to the extent that i the Product is properly and c...

Страница 5: ...uipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Страница 6: ...icate CE mark by EU Tec certificate xxxxxxxxxxx United Kingdom UK UKCA mark by DOC Australia New Zealand SDOC approval RCM mark by SDOC from E7689 Japan certificates R 003 200139 R 209 J00306 T D20011...

Страница 7: ...earn about the special features of this product Trackunit assumes that you are familiar with Microsoft Windows Related Information The Trackunit web site is found at www trackunit com This site links...

Страница 8: ...he TU600A There is risk of explosion or fire if an incorrect type replacement battery is forced into the battery holder as contact may generate a short circuit Additionally the battery holder will be...

Страница 9: ...manufacturers of the medical devices to determine if they are adequately shielded from external RF energy Physicians may be able to assist in obtaining this information The TU600A unit cannot be turne...

Страница 10: ...uel or chemical transfer or storage facilities vehicles using liquefied petroleum gas such as propane or butane areas where the air contains chemicals or particles such as grain dust or metal powders...

Страница 11: ...ty during operation For operational safety the battery inside the TU600A is under constant environmental temperature control providing the following automatic battery safety The battery can only be ch...

Страница 12: ...Simply connect the unit to supply voltage 12V 24V 48V DC In its default configuration reports are sent nominally at 15 minute intervals or faster whenever there is motion Upon powering up the device...

Страница 13: ...neath metal parts To reduce hum and noise in the FM radio it is recommended to place the unit at a minimum distance of 20 inches 50 cm from the radio or the loudspeakers Installation for insurance and...

Страница 14: ...case of a short circuit etc Digital inputs The activation of a digital input requires a minimum high level voltage of 9 5V Digital output The digital output has the type indication LO side switch that...

Страница 15: ...erating hours To avoid this situation the digital input 4 Pink wire should be connected to the chassis ground on the machine Then send the following SMS to the unit phone number to activate the filter...

Страница 16: ...TU600A Trackunit TU600A Technical Manual v1 1 June 2021 Page 16 Functionality check...

Страница 17: ...ackunit TU600A Technical Manual v1 1 June 2021 Page 17 Verify my Trackunit In order to control if the installation of the TU600A unit has been done correctly it is possible to use the Verify my Tracku...

Страница 18: ...n the unit is off thus no power on the unit Check if the installation is performed correctly according to the guidelines of this manual F3 The LED is constant red thus the unit is not attached to the...

Страница 19: ...etc The current consumption of the relay must not exceed 200 mA DC current and the relay contacts must be specified to withstand the load that needs to be controlled NOTE The output can only handle D...

Страница 20: ...ckunit holds no liability for any damages occurred to persons vehicles moving machines construction machines etc caused by wrong installation and or faulty use of the digital output Warranty Trackunit...

Страница 21: ...ply voltages Can be ordered at Trackunit APS a Supply voltage 12V 24V Max 30A i ATO blade fuses Max 32V 1A used with Littelfuse FHAC0002SXJ fuse holder Standard ii ATP blade fuse Max 32V 1A ATO style...

Страница 22: ...upport ticket number will be created in our system You will receive your ticket number by email 2 In case your hardware needs to be sent to us you will receive an RMA form by email from our support te...

Страница 23: ...supply voltage outside the charging temperature range 20 C to 50 C Internal storage with loss of battery performance Within battery safety limits According to the MSDS UN38 3 and IEC62133 2012 testin...

Страница 24: ...807 824 MHz RX 852 869 MHz Sub 850 MHz band B28 TX 703 748 MHz RX 758 803 MHz B66 TX 1710 1780 MHz RX 2110 2200 MHz B85 TX 698 716 MHz RX 728 746 MHz LTE FDD cat NB2 B1 TX 1920 1980 MHz RX 2110 2170...

Страница 25: ...ns Length 122 1 mm Width 45 65 mm 49 mm incl mounting cradle Height 18 mm 23 mm incl mounting cradle Cable length 170 180 cm Environmental class IP67 Standalone IP66K IP69K Mounted with HW shield Encl...

Страница 26: ...o the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation D clar...

Страница 27: ...arantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipmen...

Страница 28: ...plies with the essential and environmental requirements of the Interoperability of trans European conventional rail system 2001 16 EC and 2004 50 EC directives when used as intended on rolling stock T...

Страница 29: ...rks Specific Trackunit model design certificates have been obtained for Bluetooth SIG registration The TU600 15 product is Bluetooth SIG registered under declaration ID D046156 supporting core specifi...

Страница 30: ...C CE mark Yes UK TU600 15 BSI UKCA mark Yes Myanmar TU600A PTD NOTE Accept EU DoC for Import if requested No Japan TU600A TELEC JATE MIC R 003 200139 R 209 J00306 T D200116003 Yes Australia New Zealan...

Страница 31: ...IEC 60068 2 64 2010 Acceleration IEC 60721 2 3 2013 Attitude SAEJ1455 2017 EN IEC 60068 2 78 2001 Damp heat steady state EN IEC 60068 2 5 ASTM D4329 2018 2013 UV protection SAEJ1455 2017 IEC 60529 A1...

Страница 32: ...TU600A Trackunit TU600A Technical Manual v1 1 June 2021 Page 32 Environmental protection without HW shield...

Страница 33: ...TU600A Trackunit TU600A Technical Manual v1 1 June 2021 Page 33 Environmental protection with use of HW shield Trackunit Aps Gasvaerksvej 24 4 sal DK 9000 Aalborg Denmark...

Отзывы: