Printed in the Federal Republic of Germany
TR-Electronic GmbH 2016, All Rights Reserved
10/31/2018
TR - ECE - BA - DGB - 0131 - 02
Page 77 of 103
6.2 Configuration
6.2.1 PNO Class 1 16-bit resolution, identifier 0xD0
The measuring system uses one input word only, which is consistently transferred via
the bus.
Input word IW x
Data byte 1
Data byte 0
LSB
MSB
Input byte x+0
Input byte x+1
Relevant parameter data:
•
Count sequence
6.2.2 PNO Class 1 32-bit resolution, identifier 0xD1
The measuring system uses two input words only, which are consistently transferred
via the bus.
Double input word ID x
Data byte 3
Data byte 2
Data byte 1
Data byte 0
LSB
MSB
Input byte x+0
Input byte x+1
Input byte x+2
Input byte x+3
Relevant parameter data:
•
Count sequence
In the case of configurations for CLASS 1, preset adjustment is not possible via the
PROFIBUS, and only the code sequence can be changed. The measuring system
operates with the standard resolution specified on the rating plate. The diagnostic
data are limited to 16 bytes.