Configuration and Parameterization
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 76 of 103
TR - ECE - BA - DGB - 0131 - 02
10/31/2018
6.1 Overview
Configuration Operating parameters
*·
Length Features
PNO Class 1
Page 77
- Count direction
16 bit IN
- No measuring system scaling, the measuring
system has the base resolution according to the
nameplate
- 16 byte diagnosis data
- Count direction
PNO Class 1
Page 77
- Count direction
32 bit IN
PNO Class 2
Page 78
- Count direction
- Class 2 on/off
- Commissioning diagnostics
- Scaling function
- Steps per revolution
- Total measuring range
16 bit IN
16 bit OUT
- Measuring system scaling is possible, however
the number of steps / revolution must be an
integer and the number of revolutions an
exponent of 2
- Preset adjustment via the bus
- Count direction
PNO Class 2
Page 78
- Count direction
- Class 2 on/off
- Commissioning diagnostics
- Scaling function
- Steps per revolution
- Total measuring range
32 bit IN
32 bit OUT
TR-Mode
,
Position
Page 79
- Count direction
- Commissioning diagnostics
- Short Diagnostics
- Total measuring range
- Revolutions numerator
- Revolutions denominator
- Code SSI-Interface
- Data bits SSI-Interface
- Code PROFIBUS-Interface
- Preset
- Limit switch
32 bit IN
32 bit OUT
- Measuring system scaling possible, the number
of steps per revolution can be a decimal number
and the number of revolutions any number (not a
exponent of 2).
- Preset adjustment via the bus
- Count direction
- Configuration of the SSI interface
- Output code programming
- Preselection of the values for the external Preset
inputs
- Limit switch
TR-Mode
,
- Po
- Velocity
Page 80
- Count direction
- Commissioning diagnostics
- Short Diagnostics
- Total measuring range
- Revolutions numerator
- Revolutions denominator
- Code SSI-Interface
- Data bits SSI-Interface
- Code PROFIBUS-Interface
- Preset
- Limit switch
- Velocity
32 bit IN
16 bit IN
32 bit OUT
- Measuring system scaling possible, the number
of steps per revolution can be a decimal number
and the number of revolutions any number (not a
exponent of 2).
- Preset adjustment via the bus
- Count direction
- Configuration of the SSI interface
- Output code programming
- Preselection of the values for the external Preset
inputs
- Limit switch
- Velocity output
*
from the bus master perspective