8.1 Object 2000h: Mode selection TR / CiA DS-406
With the mode selection can be selected which scaling parameter should be used.
Normally the parameters according to the encoder profile CiA DS-406 are used. For
special applications it can be switched over to TR parameter to use expanded gear
functions.
Index
2000h
Description
TR-Parameter used
Data type
UNSIGNED16
Category
Optional
Access
rw
PDO mapping
No
Lower limit
0x0000 = CiA DS-406 mode
Upper limit
0x0001 = TR mode
Default
0x0000
Only the parameters in the active mode can be changed. Not listed objects apply for
both modes.
CiA DS-406 mode
TR mode
6000h, Counting direction
2001h, Counting direction