Communication specific standard objects (CiA DS-301)
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 108 of 127
TR - ECE - BA - DGB - 0128 - 01
11/20/2018
7.1 Object 1000h: Device type
Contains information about the device type. The object at index 1000h describes the
type of device and its functionality. It is composed of a 16 bit field which describes the
device profile that is used (Device Profile Number 406 = 196h) and a second 16 bit
field which gives information on the type of encoder.
Unsigned32
Device Type
Device Profile Number
Encoder Type
Byte 0
Byte 1
Byte 2
Byte 3
196h
2
7
to 2
0
2
15
to 2
8
Encoder Type
Code
Definition
Default
01
Single-Turn absolute rotary encoder
02
Multi-Turn absolute rotary encoder
X
7.2 Object 1001h: Error register
The error register displays bit coded the error state of the measuring system. Also
several errors at the same time can be displayed by a set bit. The more exact error
cause can be taken from the bits 0-15 of the object 1003h. An error is signaled at the
moment of the occurrence by an EMCY message.
Unsigned8
Bit
Meaning
0
generic error
1
0
2
0
3
0
4
communication error (overrun, error state)
5
0
6
0
7
0
7.3 Object 1002h: Manufacturer status register
This object is not used by the measuring system, by read access the value is always "0".