6.1 Connection
The shielding is to be connected
with large surface on the mating
connector housing!
X1
PORT-IN Female socket (M12x1-4 pin. D-coded)
1
TxD+
Transmission Data +
2
RxD+
Receive Data +
3
TxD
–
Transmission Data -
4
RxD
–
Receive Data -
X2
PORT-OUT Female socket (M12x1-4 pin. D-coded)
1
TxD+
Transmission Data +
2
RxD+
Receive Data +
3
TxD
–
Transmission Data -
4
RxD
–
Receive Data -
X3
Male socket (M12x1-4 pin. A-coded)
1)
1
11
– 27 V DC
Encoder-Supply Voltage
2
RS-485+
Programming Interface (TRWinProg)
1)
3
0 V
Encoder-Supply Voltage
4
RS-485-
Programming Interface (TRWinProg)
Order numbers for the Ethernet connector, suitably for the D-coded female socket
M12x1-4 pin.
Manufacturer
Name
Art-No.:
Binder
Series 825
99-3729-810-04
Phoenix Contact
SACC-M12MSD-4CON-PG 7-SH (PG 7)
15 21 25 8
Phoenix Contact
SACC-M12MSD-4CON-PG 9-SH (PG 9)
15 21 26 1
Harting
HARAX
M12-L
21 03 281 1405