5.2.10 Cyclic time
(μs)
For the cycle time, a value between 0 μs and 1 000 000 μs (1 sec.) can be set.
lower limit
0
upper limit
1 000 000
default
9875
If the cycle time is too short, it is automatically set to the minimum cycle time.
The minimum cycle time in μs is calculated as follows:
Cycle time_min = (1 / baud rate) * number of bit per sign * (number of signs + 1.5) * 1.000.000
5.3 Actual values
In the online state in the field
Position
the current measuring system position and in
the field
1/min
the actual velocity value is displayed.
With entering of a value into the field
Position
the measuring system can be
adjusted on the desired position value. The new position is set if the function
Data
write to device
is executed.
Origin type
Desired position value
< programmed Total number of steps