User's Guide l MBox-R/V UG 0103 l © 2017 TQ-Group
Page 6
4.
FUNCTIONAL SPECIFICATION
4.1
Electrical Specification
4.1.1
Supply Voltage Characteristics
The MBox-R/V supports a wide-range voltage input of 9 to 36 V DC.
4.1.2
Power Consumption Specification
The power consumption of the system significantly depends on the configuration and the connected devices (COM Express™
module, mass storage devices, USB devices etc.). The maximum input current of the MBox-R/V is limited to 5 A by a fuse.
The devices connected to the carrier should not exceed 30 W.
Note: Power requirement
The power supply for the MBox-R/V must be configured with enough reserve.
It should be calculated with the maximum power of all connected components.
4.2
Environmental Specification
•
Temperature Operating / Extended:
The maximum operating temperature depends on the internal power dissipation which is mainly influenced by the
CPU version. The following temperature parameters were determined by qualification tests (standard configurations
without any add-on cards):
Table 4:
CPU Overview
CPU
E3845
E3827
E3825
E3815
E3805
CPU Cores
4
2
2
1
2
Cache
2 Mbyte
1 Mbyte
1 Mbyte
512 Kbyte
1 Mbyte
CPU clock
1.91 GHz
1.75 GHz
1.33 GHz
1.46 GHz
1.33 GHz
Temp. T
junction
–40 °C to +110 °C
–40 °C to +110 °C
–40 °C to +110 °C
–40 °C to +110 °C
–40 °C to +110 °C
Memory Speed
1,333 MT/s
1,333 MT/s
1,067 MT/s
1,067 MT/s
1,067 MT/s
Max. memory
8 Gbyte
8 Gbyte
8 Gbyte
8 Gbyte
8 Gbyte
Memory configuration
Single, w ECC
Single, w ECC
Single, w ECC
Single, w ECC
Single, w ECC
Graphics
Intel® HD Graphics
Intel® HD Graphics
Intel® HD Graphics
Intel® HD Graphics
None
GFX Base / Burst
542 / 792 MHz
542 / 792 MHz
533 / 533 MHz
400 / 400 MHz
–
TDP
10 W
8 W
6 W
5 W
3 W
MBox temp range
–40 °C to +60 °C
–40 °C to +70 °C
The supported operating temperature range depends on the components and modules used, e.g. if the temperature of the
COM Express™ module is in the range of 0 °C to +60 °C, the maximum operating temperature range is 0 °C to +60 °C.
•
Storage temperature:
–40 °C to +85 °C
•
Relative humidity (operating / storage):
10 % to 90 % (not condensing)
Note: Environmental conditions
When powering the MBox-R/V, make sure the chassis is not covered by any objects.
Otherwise the heat dissipation will be restricted by physical effects and the maximum operating
temperature will be reduced.