background image

 

 

 

 

 

 

 

 

 

Pad Staff Workstation

 

Model 895 

 

 

 

 

PRERELEASE DOCUMENTATION

 

 

Site Planning Guide 

 
 

 

 
 

 

 
 
 

 

3M Security Systems Division 

3M Center, Building 225-4N-14 

St. Paul, Minnesota  55144-1000 

78-8126-xxxx-x  Rev 1 

Copyright © 2004 3M IPC. All rights reserved. 

Содержание 895

Страница 1: ...rkstation Model 895 PRERELEASE DOCUMENTATION Site Planning Guide 3M Security Systems Division 3M Center Building 225 4N 14 St Paul Minnesota 55144 1000 78 8126 xxxx x Rev 1 Copyright 2004 3M IPC All rights reserved ...

Страница 2: ...try Canada Radio Frequency Rules and Regulations 6 EMC Compliance Europe 6 Section 1 Overview 7 Reader pad 8 Reader 8 Cable lengths 9 Serial cable 9 Reader pad cable 9 Power cables 9 Section 2 Basic Operation 10 Pad Staff Workstation Software 10 Section 3 Care and maintenance 11 Cleaning the reader pad 11 Requesting service 11 Before you call 11 3M Service Phone Numbers 11 ...

Страница 3: ...erform the above functions using 3M D8 RFID tags The 3M Pad Staff Workstation Model 895 is intended for use in an indoor library environment It has not been evaluated for other uses or locations EXPLANATION OF SIGNAL WORD CONSEQUENCES DANGER Indicates a potentially hazardous situation which if not avoided will result in death or serious injury and or property damage WARNING Indicates a potentially...

Страница 4: ...ovement which if not avoided may result in minor or moderate injury Operation of the RFID Pad may involve repeated body movements To minimize possibility of Repetitive Stress Injury avoid prolonged repetitive movements rest when becoming fatigued and when possible alternate job functions with other people Avoid awkward reaching for items To reduce the risks associated with environmental contaminat...

Страница 5: ...quipment Regulations Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired oper...

Страница 6: ...ules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NO MODIFICATIONS Modifications to this device shall not be made without the written consent of The 3M Company Unauthorized modifications may void the authority granted under Feder...

Страница 7: ...rogram 3M RFID Tags Reader pad components The reader pad includes the following components 3M RFID Reader Pad 3M RFID Reader Serial cable connects the RFID reader to a customer supplied computer Power transformer power cord 895_SPG_002 Serial Cable Power Transformer RFID Reader Customer supplied Computer Reader Pad 3 ...

Страница 8: ...ical ambient temperature range 50 F to 104 F 10 C to 40 C Humidity 0 to 85 RH non condensing Reader Dimensions Length 5 6 in 14 22 cm Width 5 0 in 12 7 cm Height 1 0 in 2 54 cm Weight 3 64 oz 103 2 g Environmental Typical ambient temperature range 50 F to 104 F 10 C to 40 C Humidity 0 to 85 RH non condensing Electrical 100 240 Vac 47 to 63 Hz 0 5 A ...

Страница 9: ...length not to exceed 50 ft 15 25 meters Power cables AC power cord from the power transformer to an AC power receptacle 6 7 ft 2 meter Power transformer cable from the power transformer to the RFID Reader 6 7 ft 2 meter 895_SPG_006 Reader Pad Cable to Reader 6 7 ft 2 meter Serial Cable to computer 6 5 ft 2 meter Power Transformer Cable 6 7 ft 2 meter Power Transformer AC power cord 6 7 ft 2 meter ...

Страница 10: ...tware secures and un secures tags as required The Pad Staff Workstation software can perform the following operations Check In and Check Out Send IDs to circulation and secure or un secure items Send ID Send item identifiers read from tags to the library circulation system Secure Un Secure Only Change the status of items security without sending IDs to the circulation system Read Tags Only Read an...

Страница 11: ...you call 3M Service have the following information available Have the reader pad connected with power applied and near the telephone Write down the reader pad s serial number located on the bottom of the reader pad Be ready to describe the problem and any error messages in detail 3M Service Phone Numbers For any questions regarding the reader pad hardware call one of the following telephone number...