background image

 

User's Manual  l  MB-M10-1 UM 0100  l  © 2016 TQ-Group 

 

Page  2 

 

1.6

 

Tips on Safety 

Improper or incorrect handling of the product can substantially reduce its life span. 
 

1.7

 

Symbols and Typographic Conventions 

Table 1: 

Terms and Conventions 

Symbol 

Meaning 

 

This symbol represents the handling of electrostatic-sensitive modules and / or components. These 
components are often damaged / destroyed by the transmission of a voltage higher than about 50 V.  
A human body usually only experiences electrostatic discharges above approximately 3,000 V. 

 

This symbol indicates the possible use of voltages higher than 24 V. 
Please note the relevant statutory regulations in this regard. 
Non-compliance with these regulations can lead to serious damage to your health and also cause 
damage / destruction of the component. 

 

This symbol indicates a possible source of danger. Acting against the procedure described can lead to 
possible damage to your health and / or cause damage / destruction of the material used. 

 

This symbol represents important details or aspects for working with TQ-products. 

Command 

A font with fixed-width is used to denote commands, contents, file names, or menu items. 

 

1.8

 

Handling and ESD Tips 

General handling of your TQ-products 

 

The TQ-product may only be used and serviced by certified personnel who have taken note of the 
information, the safety regulations in this document and all related rules and regulations. 
A general rule is: do not touch the TQ-product during operation. This is especially important when 
switching on, changing jumper settings or connecting other devices without ensuring beforehand 
that the power supply of the system has been switched off. 
Violation of this guideline may result in damage / destruction of the MB-M10-1 module and be 
dangerous to your health. 
Improper handling of your TQ-product would render the guarantee invalid. 

 
Proper ESD handling 

 

The electronic components of your TQ-product are sensitive to electrostatic discharge (ESD). 
Always wear antistatic clothing, use ESD-safe tools, packing materials etc., and operate your TQ-
product in an ESD-safe environment. Especially when you switch modules on, change jumper settings, 
or connect other devices. 

 

Содержание MB-M10-1

Страница 1: ...User s Manual l MB M10 1 UM 0100 l 2016 TQ Group Page 1 MB M10 1 User s Manual MB M10 1 UM 0100 2016 04 01...

Страница 2: ......

Страница 3: ...ts 7 3 4 1 Gigabit Ethernet Controller 7 3 5 Connectors and Interfaces 7 3 5 1 Power Supply 9 3 5 2 Mini DisplayPort 9 3 5 3 USB Host Device Interfaces 9 3 5 4 Gigabit Ethernet 10 3 5 5 Serial Interfa...

Страница 4: ...11 Further Applicable Documents and Links 19 ILLUSTRATION DIRECTORY Illustration 1 D Sub 9 Adapter Cable 5 Illustration 2 Block Diagram MB M10 1 6 Illustration 3 MB M10 1 Top 7 Illustration 4 MB M10 1...

Страница 5: ...d trademarks are rightly protected by a third party 1 3 Disclaimer TQ Systems GmbH does not guarantee that the information in this User s Manual is up to date correct complete or of good quality Nor d...

Страница 6: ...symbol represents important details or aspects for working with TQ products Command A font with fixed width is used to denote commands contents file names or menu items 1 8 Handling and ESD Tips Gener...

Страница 7: ...used for example CompactFlash cards are to be taken note of They contain if applicable additional information that must be taken note of for safe and reliable operation These documents are stored at T...

Страница 8: ...fanless 2 1 Functional Overview The following key functions are implemented on the MB M10 1 Supported Modules COM Express Mini Modules with Type 10 pinout External Interfaces 2 Gigabit Ethernet 2 USB3...

Страница 9: ...OL DSUB PICOBLADE REV 0100 has the order code 278622 0100 It is 130 mm long and connects the internal connector X11 with a 9 pin D Sub connector Illustration 1 D Sub 9 Adapter Cable Please contact sup...

Страница 10: ...on of the MB M10 1 itself is approximately 50 mA 12 V COM Express module supplied externally UEFI shell active no keyboard no mouse no mass storage device no Ethernet cable etc connected The maximum i...

Страница 11: ...000 Mbps speed and IEEE1588 support Please contact support tq group com for further information about the IEEE1588 support 3 5 Connectors and Interfaces Illustration 3 MB M10 1 Top Reset Button X7 mic...

Страница 12: ...M10 1 UM 0100 l 2016 TQ Group Page 8 Illustration 4 MB M10 1 Bottom X9 Serial 0 RS232 X12 mSATA socket X16 Mini PCIe socket X17 FAN connector X10 Front panel connector X11 Serial 1 RS232 X15 Mini PCI...

Страница 13: ...adapters from mini DP to HDMI DVI or VGA depends on the combination of the COM Express module and the adapter used The combination of some modules with some adapters might not work Illustration 5 mini...

Страница 14: ...A79 SER1_CTS 3 3 V output The four COM Express serial signals RX TX are specified to provide protection and level shifter circuitry To implement this circuitry would lead to lower transfer speeds of...

Страница 15: ...or micro SD cards The SDIO signals on COM Express modules can also be used as GPIO signals Please ensure that the module is configured for SDIO usage of these pins 3 5 9 Fan Connector The MB M10 1 pro...

Страница 16: ...ED State LED Colour Description Off S5 State System is shut down or not powered On Green S0 State System is running On Orange S3 State System is in Sleep mode 3 5 12 COM Express Connector The EPT 401...

Страница 17: ...designed for standard 100 mm chassis The mounting holes are positioned to support eNUC compatible chassis as well The following illustration shows the MB M10 1 Illustration 11 MB M10 1 Dimensions Plea...

Страница 18: ...1 3D View Assembly The CPU module is mounted to the heat spreader with distance bolts The CPU module heat spreader unit is mounted with screws from bottom side to the mainboard 4 3 Protection Against...

Страница 19: ...oup com for further information about supported Operating Systems 5 1 2 Driver Download The MB M10 1 module is well supported by the Standard Operating Systems which already include most of the requir...

Страница 20: ...bservance of the WEEE regulation To be able to reuse the product it is produced in such a way a modular construction that it can be easily repaired and disassembled 6 5 Other Entries By environmentall...

Страница 21: ...ry EMC Electromagnetic Compatibility eSATA external Serial ATA ESD Electrostatic Discharge FAE Field Application Engineer FIFO First In First Out flexiCFG Flexible Configuration FPGA Field Programmabl...

Страница 22: ...M Pulse Width Modulation PWR Power RMA Return Merchandise Authorization RoHS Restriction of the use of certain Hazardous Substances RTC Real Time Clock SATA Serial ATA SCU System Control Unit SD Secur...

Страница 23: ...le Base Specification Rev 2 1 May 14 2014 PICMG 2 PICMG COM Express Carrier Design Guide available for public download https www picmg org wp content uploads PICMG_COMDG_2 0 RELEASED 2013 12 061 pdf R...

Страница 24: ......

Страница 25: ...TQ Systems GmbH M hlstra e 2 l Gut Delling l 82229 Seefeld info tq group com l www tq group com...

Отзывы: