User's Manual l MB-COME6-4 UM 0100 l © 2022, TQ-Systems GmbH
Page 14
3.5.7
LVDS
The MB-COME6-4 provides a LVDS interface where suitable displays can be directly connected.
To select the LVDS interface on the MB-COME6-4 the DIP switch on the carrier has to be set to the “LVDS” position.
This functionality is only available if the COM Express™ module provides the LVDS interface.
There are also connectors to power the backlight of the connected display.
The MB-COME6-4 has an on board EDID EEPROM to store display specific timing information. The EEPROM can be programmed
with an external I
2
C programmer. If the programmer supports 3.3 V output voltage, the MB-COME6-4 can be programmed
without any additional power supply. In this case no COM Express™ module should be connected to the carrier board.
X27:
LVDS connector
−
Connector type:
Hirose DF19G-30P-1H
−
Mating connector:
Hirose DF19-30S-1C
Table 8:
LVDS Connector
Figure 8: LVDS Connector
Pin
Signal
Remark
1
A0–
Odd bus
2
A0+
Odd bus
3
A1–
Odd bus
4
A1+
Odd bus
5
A2–
Odd bus
6
A2+
Odd bus
7
GND
–
8
ACLK–
Odd bus
9
ACLK+
Odd bus
10
A3–
Odd bus
11
A3+
Odd bus
12
B0–
Even bus
13
B0+
Even bus
14
GND
–
15
B1–
Even bus
16
B1+
Even bus
17
GND
–
18
B2–
Even bus
19
B2+
Even bus
20
BCLK–
Even bus
21
BCLK+
Even bus
22
B3–
Even bus
23
B3+
Even bus
24
GND
–
25
5V_PANEL
5 V Panel supply voltage
26
5V_PANEL
27
5V_PANEL
28
3V3_PANEL
3.3 V Panel supply voltage
29
3V3_PANEL
30