TPS WP-Sim Скачать руководство пользователя страница 1

Congratulations !

 

The 

WP-Sim

 is a complete pH, ORP, Conductivity, TDS and 

Temperature simulator for TPS instruments. The 

WP-Sim

 provides an 

indispensable tool for checking the operation of instruments without 
sending them to the factory for service. 

The manual is divided into the following sections: 

1. 

Table of Contents

 

Each major section of the handbook is clearly listed. Sub-sections 
have also been included to enable you to find the information you 
need at a glance. 

2. 

Introduction

 

The introduction has a diagram and explanation of the display and 
controls of the 

WP-Sim

. It also contains a full listing of all of the items 

that you should have received with your 

WP-Sim

. Please take the 

time to read this section, as it explains some of items that are 
mentioned in subsequent sections. 

3. 

Main Section

 

The main section of the handbook provides complete details for 
operation of the 

WP-Sim

Содержание WP-Sim

Страница 1: ...handbook is clearly listed Sub sections have also been included to enable you to find the information you need at a glance 2 Introduction The introduction has a diagram and explanation of the display and controls of the WP Sim It also contains a full listing of all of the items that you should have received with your WP Sim Please take the time to read this section as it explains some of items tha...

Страница 2: ...treet Springwood Brisbane Australia 4127 Phone 07 32 900 400 International 61 7 32 900 400 Fax 07 3808 4871 International 61 7 3808 4871 Email tps tps com au Web www tps com au Model WP Sim Multi Function Simulator Version 1 0 Date 12 12 2002 Author MS ...

Страница 3: ...ons 7 2 Simulating pH Values 8 3 Simulating Millivolt Values 9 4 Simulating Conductivity and TDS Values 10 5 Simulating Temperature Values 11 6 Simulating pH ORP Temperature for Pool Controllers 12 7 Impedance Test for pH 14 8 Testing the WP Sim Battery 16 9 Changing the WP Sim Battery 17 10 Warranty 18 ...

Страница 4: ...Page 4 1 Introduction 1 1 WP Sim Illustration ...

Страница 5: ...nductivity and TDS values The values are simulated by a precision resistor network so the Function switch can be left in the OFF position for these tests See section 4 Function Switch Used to select ON OFF Impedance section 7 or Battery Test section 8 pH mV Output Connector All pH and Millivolt signals are output through this connector Conductivity TDS Temperature Output Connector All Conductivity...

Страница 6: ...P Sim Handbook 130050 Output Cables that may have been ordered with your WP Sim 1 pH mV Output Cable with TPS4 plug 130132 2 Conductivity TDS Output Cable with 5 Pin DIN plug 130133 3 Conductivity TDS Output Cable with 6 Pin Waterproof plug 130134 4 Conductivity TDS Output Cable with 7 Pin Waterproof plug 130135 5 Conductivity TDS Output Cable with 9 Pin Waterproof plug 130136 6 pH PLUS mV Output ...

Страница 7: ... 01 10 mS cm 0 100 mS cm 5 TDS 01 000 ppM 10 000 ppM 5 Temperature Current temperature inside WP Sim unit Can be up to 10 O C offset All output values other than Temperature are simulated for 25 O C Power 9V Alkaline Battery for 100 hours of continuous operation Dimensions 187 x 110 x 51 mm Mass Approx 200g Environment Temperature 0 to 45 O C Humidity 0 to 90 R H ...

Страница 8: ...on switch to ON Switch the instrument under test on and select pH mode See the instrument s handbook if necessary 4 Use the pH mV selector to output any of the 5 simulated pH values The readout of the instrument under test should approximately correspond to the simulated pH value selected on the WP Sim Variations are possible due to the current temperature and calibration settings of the instrumen...

Страница 9: ...ment under test as per the example diagram below 3 Switch the WP Sim Function switch to ON Switch the instrument under test on and select Millivolt mode See the instrument s handbook if necessary 4 Switch the pH mV selector to 650 mV The readout of the instrument under test should be approximately 650 mV Variations are possible due to the current calibration settings of the instrument under test ...

Страница 10: ...TDS output Switch the instrument under test on and select Conductivity or TDS mode as required See the instrument s handbook if necessary 4 Use the Conductivity TDS selector to output any of the 4 simulated Conductivity or 2 simulated TDS values The readout of the instrument under test should approximately correspond to the simulated Conductivity or TDS value selected on the WP Sim Variations are ...

Страница 11: ...e other end to the instrument under test as per the example diagram below 3 The WP Sim does not need to be switched on for Temperature output Switch the instrument under test on and select Temperature mode See the instrument s handbook if necessary 4 The output will correspond to the current temperature inside the WP Sim Variations are possible due to the calibration settings of the instrument und...

Страница 12: ...0 and easyCHEM 660 1 Obtain the correct Pool Controller output cable for the instrument under test 2 Each end of the cable is labelled as the WP Sim or Pool Controller end Connect the cable to the WP Sim and the pool controller correctly as per the example diagram below 3 Switch the WP Sim Function switch to ON Switch the instrument under test on Continued over the page ...

Страница 13: ...isplay the current temperature inside the WP Sim Variations are possible due to the current calibration settings of the instrument under test Note As the WP Sim is simultaneously outputting pH and mV values you will notice that BOTH readings on the display change when the pH mV selector is changed Please disregard the pH values when the WP Sim is set to 650 mV and disregard the mV reading when the...

Страница 14: ...onent failure corrosion etc accuracy will be affected and the pH sensor may suffer permanent damage To test the impedance of the pH meter s input circuit 1 Obtain the correct pH mV output cable for the instrument under test 2 Connect one end of the pH mV output cable to the WP Sim and the other end to the instrument under test as per the example diagram below 3 Switch the WP Sim Function switch to...

Страница 15: ...urrent temperature and calibration settings of the instrument under test Please note that the simulated values are for 25 O C 5 Make a note of the reading obtained on the display 6 Now switch the WP Sim Function switch to Impedance The pH value on the instrument s display should change by less than 0 05pH if it s input impedance is high enough If the display changes by more than this amount the in...

Страница 16: ...equipped with a Battery Test function To check the battery set the Function switch to Battery Test The red light on the front panel will glow brightly if the battery is OK If the light is very dim or does not operate at all the battery must be replaced ...

Страница 17: ...WP Sim CAUTION THERE ARE WIRES THAT CONNECT THE CIRCUIT BOARD TO THE CONNECTORS TAKE CARE WHEN OPENING THE METER TO ENSURE THESE WIRES ARE NOT BROKEN Do not lose the nylon washers as these form a part of the waterproof seal when the screws are replaced 3 Replace the battery with a new alkaline 9V battery 4 Re fit the rear of the WP Sim and replace the Instrument Case Screws ...

Страница 18: ... the equipment Shipping damage is not covered by this warranty Please note A guarantee card is packed with the instrument or sensor This card must be completed at the time of purchase and the registration section returned to TPS Pty Ltd within 7 days No claims will be recognised without the original guarantee card or other proof of purchase This warranty becomes invalid if modifications or repairs...

Страница 19: ...ime phone number Your company name ORDER number and return street address A description of the fault Please be specific Note Please Repair does NOT describe a fault Your equipment will be repaired and returned to you by air express where possible For out of warranty units a repair cost will be calculated from parts and labour costs If payment is not received for the additional charges within 30 da...

Отзывы: