background image

ECO 1-7639  060220   REV.-   FORM: 8224

4 of 4

THERMOSTAT INSTALLATION INSTRUCTIONS

Determine the location where the thermostat is to be mounted. It should be installed about 54” above floor level where there 

is good air circulation. Avoid heat sources such as lamps,direct sunlight, fireplaces or walls containing air conditioning and 

heating ducts. Do not install where anything can obstruct free air flow such as drapes or doors.

1.  Disconnect the power supply to the HotPod. 
2.  Follow instructions included with the thermostat for installation procedures.
3. 

Choose a proper location for the thermostat following instructions outlined above. Insure proper fit. for dimensions see 

below (FIG 4).

4. 

For the thermostat connection remove approximately 2 1/2” of the outer jacket and strip the individual conductors 

approximately 1/4”

. Use electrical materials approved by applicable codes.  

5.  Feed electrical wires from the system through the opening in wall plate. Wiring must not interfere with the operation of 

the thermostat.  

6.  Connect the wires to the proper terminals. (See Fig.3) 
7. 

Once you have finished installing the thermostat in the desired location, restore power to the Hotpod.

8.  Refer to instructions included with the thermostat for setup and operating details.  

THERMOSTAT SETUP INSTRUCTIONS

Once you have restored power to the Hotpod the thermostat will begin to operate.
1.  Press and Hold the 

+

 and 

-

 buttons for 3 seconds

2.  Select TECH button at lower left
3. 

Configure  the installer options as you desire by changing the settings using the 

+

 or 

-

 buttons. Press PREV or 

NEXT buttons to move from one step to another.

4.  THE FOLLOWING STEPS MUST BE CHOSEN FOR THE HOTPOD SYSTEM TO WORK CORRECTLY. 
5.  Step 1: Your preference
6.  Step 2: 

COMP DELAY

 set to

 OF

7.  Step 3 through 8: Your preference
8.  Step 9: 

SYS MODE

 set to 

HC

 

9.  Step 10: 

FAN OPER

 set to 

EL

10. 

To exit TECH setup: press and hold the 

+

 and 

-

 buttons for 3 seconds, or wait 20 seconds.

11. 

For Wifi setup: follow instructions included with the thermostat.

Fig. 4

Содержание HotPod EHP6-10002CT

Страница 1: ...that you can insert male crimped end into inlet side of the HotPodTM Discharge end must point toward outlet register arrows show air flow direction Position wiring enclosure to allow permanent access to the wiring compartment INSTALL HotPodTM 1 Remove 9 22 9 cm section of duct for the 6 HotPod or 9 1 2 for the 8 HotPod Allow an additional 5 12 7cm for the optional Silent Boot For Rigid Metal Duct ...

Страница 2: ...R PERMANENT WIRED MODELS 1 Remove wiring cover Following all local codes connect to 120 Vac 15 amp dedicated circuit for 1000w models and 120 Vac 20amp dedicated circuit for 1440w models Provide strain relief for all wiring A Black hot wire to L1 terminal See Fig 2 B White neutral wire to NEUT terminal See Fig 2 C Green or ground wire to green housing ground screw CORD CONNECTED MODELS For cord co...

Страница 3: ...hermostat cable approximately 3 1 2 inches from stripped end Using a pair of pliers press firmly onto cable and into double d shaped hole provided in control board enclosure THERMOSTAT INSTALLATION FOR HARD WIRED THERMOSTATS Note All thermostats may not operate the HotPod correctly The thermostat must operate the fan with the heat Fig 3 R W W2 Y G C 2 5 RED R HOT WIRE WHITE W1 HEAT GREEN Y G FAN B...

Страница 4: ...s from the system through the opening in wall plate Wiring must not interfere with the operation of the thermostat 6 Connect the wires to the proper terminals See Fig 3 7 Once you have finished installing the thermostat in the desired location restore power to the Hotpod 8 Refer to instructions included with the thermostat for setup and operating details THERMOSTAT SETUP INSTRUCTIONS Once you have...

Отзывы: