ECO 1-7639 60220 REV.- FORM: 8224
1 of 4
INSTALLATION AND OPERATION INSTRUCTIONS
HotPod
TM
MODELS: EHP6-10002CT
EHP8-14402CT
INSTALLATION REQUIREMENTS
Follow All State and Local Codes.
• Each HotPod
TM
must be supplied with a dedicated 120 volt AC circuit, 15A for 1000W models, 20Amp for 1440W
models. Use 14 ga. copper wire
MINIMUM
.
• For indoor use ONLY with 6” or 8” round ductwork (depending on model).
• Units are rated for zero clearance.
CHOOSE LOCATION (Figure 1)
1. Install HotPod
TM
in a horizontal position ONLY.
2. Select a 14” (35.6 cm) section of duct that is a
MINIMUM
of 4 feet (122 cm) from outlet register.
• Select section so that you can insert male crimped end into inlet side of the HotPod
TM
.
•
Discharge end must point toward outlet register (arrows show air flow direction).
• Position wiring enclosure to allow permanent access to the wiring compartment.
INSTALL HotPod
TM
1. Remove 9” (22.9 cm) section of duct for the 6” HotPod or 9 1/2” for the 8” HotPod. Allow an additional 5” (12.7cm) for
the optional
Silent Boot.
For Rigid Metal Duct
• Crimp ends of the duct as needed to provide male ends for insertion into the HotPod
TM.
• Fasten with a minimum of 3 sheet metal screws at both ends and within 1.5” (3.8 cm) of the end of the housing. Seal
with a good quality duct tape.
For Flexible Duct
•
Attach flexible duct directly to HotPod
TM
housing using approved connection methods.