What YoU need to KnoW in adVance

ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION

Read this user manual carefully before using the appliance and keep it for future 
reference. Install this device only when it complies with local/national legislation, 
ordinances and standards. This product is intended to be used as a heater in resi-
dential houses and is only suitable for use in dry locations, in normal household 
conditions, indoors in living room, kitchen and garage.
For comfortable and safe heating ensure that there is sufficient ventilation.
Note: To avoid unexpected shut off, we recommend to put a door or window ajar 
when the heater is operating.

For each model the minimum size of space is specified in which you can use the 
heater safely, without additional ventilation 

(refer to Section J)

. If a particular 

room is smaller than the specified space, always leave a window or door slightly 
ajar (± 2.5 cm). We also recommend doing this in highly insulated or draught-free 
rooms and/or at altitudes above 1,500 metres. Do not use your heater in cellars or 
other underground areas.

Be aware that the grid and the top plate become hot. If the appliance is covered 
there is a risk of fire. Due to high surface temperature, keep away from children.

Safety system
When you have turned on the heater, if the room temperature is relatively low (19 
to 20°C) it may automatically switch off. The cause of this is build-up of heat in the 
heater.
This is a logical consequence of the safety mechanism. This will not occur when 
using the heater at lower ambient temperatures. 

ESpECIALLY FOR FRANCE: Your heater was designed to operate exclusively on fuel 
for liquid fuel-operated mobile heaters in accordance with the Decrees of 18-07-
2002 and 25-06-2010. The use of other fuels is forbidden. Ask your dealer or check 
our website for the addresses of our retailers. The liquid fuel-operated mobile 
heater is intended as an extra heater, and not as a continuous source of heat.

ESpECIALLY FOR UNITEd KINgdOM: Only use Class C1 paraffin fuel in accordance 
with BS2869; Part 2, or equivalent.

The user must comply with the following instructions for proper use:
DO NOT
- use the liquid fuel-operated mobile heater in caravans, boats, and vehicle cabins;
-  use the liquid fuel-operated mobile heater in insufficiently ventilated rooms 

(consult the table of properties for the minimum dimensions of the room to be 
heated), underground rooms and / or at a height of over 1500 metres;

-  modify the heater safety features.
The use of this type of heating in public rooms is subject to prior regulatory per-
mission. Obtain proper information on this in advance.

THE RIgHT FUEL

Your heater has been designed for use with high-quality water-free pure paraffin 
oil. Only fuels of this kind will ensure clean and proper burning. Lower quality fuel 
may result in:

 increased possibility of malfunctioning

 incomplete burning

 reduced heater lifetime

 smoke and/or smells

 deposits on the grid or mantle

Using the right fuel is therefore essential for safe, efficient, and comfortable use 
of your heater.

Damage and/or malfunctions of the heater due to the use of other than high 
quality water-free pure paraffin oil is not covered by the warranty.
Always refer to your local dealer for the right fuel for your heater.

4

This transportation cap 

is packed separately in 

the box. Only this cap 

ensures trouble-free 

transportation of the 

heater after use. 

Store it well!

Only the use of the 

correct fuel will ensure 

safe, efficient, and 

comfortable use of your 

heater.

4

Содержание zibro RS - 24

Страница 1: ...RS 24 GB OPERATING MANUAL PAGE 2 D GEBRAUCHSANWEISUNG PAGE 16 F MANUAL D UTILISATION PAGE 32 NL GEBRUIKSAANWIJZING PAGE 48 E INSTRUCCIONES DE USO PAGE 64 I ISTRUZIONI D USO PAGE 78...

Страница 2: ...s pursuing our business philosophy sharing joys in daily living We will continue to research develop and manufacture products that match people s lifestyle for efficiency safety and comfort We hope th...

Страница 3: ...e heater burns well refer to Section D Switch off the heater refer to Section E 1 2 3 4 5 6 7 As a fire precaution the tank must be filled either when the heater has been switched off or in another ro...

Страница 4: ...l operated mobile heaters in accordance with the Decrees of 18 07 2002 and 25 06 2010 The use of other fuels is forbidden Ask your dealer or check our website for the addresses of our retailers The li...

Страница 5: ...n chamber as well Fig D Put the combustion chamber back into its place The combustion chamber is positioned correctly when it can be smoothly moved a little to the left and to the right by its handle...

Страница 6: ...tes that the tank is full Never overfill the tank especially not when the fuel is very cold fuel expands when it heats up 7 Let the remaining fuel in the pump flow back into the jerrycan and carefully...

Страница 7: ...est position for ignition Section C After having ignited the heater always check whether the combustion chamber is level by sliding it slightly to the left and the right by combustion chamber handle F...

Страница 8: ...art of the heater Contact your dealer The wick height is not correct Contact your dealer THE HEATER SLOWLY EXTINGUISHES The removable tank is empty See Section B The fuel filter is contaminated by wat...

Страница 9: ...er extinguishes by itself Do this when you notice that the flame is weakening The burn out will cause some smells so it is recommended that you take the heater outside of the living room 3 Electrodes...

Страница 10: ...art re using the heater follow the instructions again starting from Section A and as specified I TRANSPORTATION Take the following measures to avoid fuel leakage during the transportation of the heate...

Страница 11: ...es of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 14 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence o...

Страница 12: ...is visible Place the burner bed next to the heater Ensure that the wiring does not become disconnected 8 Remove the screw on the stem holding the bracket and remove the bracket 9 Turn right the stem t...

Страница 13: ...number of times If the wick cannot be lowered completely it has not been placed correctly If this is the case repeat the procedure from No 12 Pull the knurled wick adjust ment knob off the heater 18 P...

Страница 14: ...1 3 cm 4 14 R...

Страница 15: ...S OFF button Knurled wick adjustment knob Combustion chamber Combustion chamber handle Fuel indicator Grill Lid for removable tank Removable tank Fuel gauge of removable tank Battery holder A B C 4 E...

Страница 16: ...r bijzondere problemen optreden die in deze ge bruiksaanwijzing niet behandeld zijn bezoekt u dan onze website www toyotomi eu of vraag de benodigde informatie op bij de afdeling Sales Support adres e...

Отзывы: