Toyotomi TGS-112CFTA-E Скачать руководство пользователя страница 3

CONTENTS

1  SAFETY PRECAUTIONS .............................................................................1

2  SELECTION OF INSTALLATION LOCATION AND PRECAUTIONS  ...2

2.1 Selection of Installation Location for Air Conditioner Unit .......................2
2.2 Selection of Installation Location ...............................................................2
2.3 Caution for Installation Where Air Conditioner Trouble is Likely to Occur

 ..........................................................................................................................2

3  INSTALLATION OF FLOOR AND CEILING TYPE INDOOR UNIT ........2

3.1 Space Dimension for Installation of the Unit .............................................2
3.2 There are 2 Styles of Installation ................................................................3
3.3 In Case of  Hanging ....................................................................................4
3.4 Electrical Wiring .........................................................................................5
3.5 Install the Drainage Pipe .............................................................................6
3.6 Install the Connection Pipes .......................................................................6
3.7 Dial-up of Unit ............................................................................................7

4  CONSTITUTES AND NAMES OF EVERY PART OF FLOOR AND 

CEILING TYPE INDOOR UNIT .....................................................................11

5  WORKING TEMPERATURE RANGE .......................................................11

6  MAINTENANCE METHOD .......................................................................11

6.1 Cleaning the Air Filters .............................................................................12
6.2 Cleaning the Unit ......................................................................................12
6.3 At the Start of the Season..........................................................................12
6.4 During the off Season ...............................................................................12

7  OPERATING INSTRUCTIONS  .................................................................13

8  MALFUNCTION ANALYZING .................................................................15

8.1 Service Center ...........................................................................................16
8.2 After-sales Service ....................................................................................16

Содержание TGS-112CFTA-E

Страница 1: ...tioners Floor and Ceiling Type Indoor Unit Please read this manual carefully before using this product and keep it properly for future reference Models TGS 28CFTA E TGS 36CFTA E TGS 50CFTA E TGS 71CFT...

Страница 2: ...top At this time change the operation mode of the indoor unit to the one that would not clash with the outdoor operating mode to make the operation normal The cooling mode is not clash with the dry mo...

Страница 3: ...llation of the Unit 2 3 2 There are 2 Styles of Installation 3 3 3 In Case of Hanging 4 3 4 Electrical Wiring 5 3 5 Install the Drainage Pipe 6 3 6 Install the Connection Pipes 6 3 7 Dial up of Unit 7...

Страница 4: ...s may shortened Do not mangle wire or adopts wires that are not recommend to use otherwise electric shock or fire may happened Please don t operate the unit by wet hand or electric shock may happened...

Страница 5: ...oom Such a place where is condensation water is easily drained out Such a place that can handle the weight of indoor unit Such a place which has easy access for maintenance Such a place where is permi...

Страница 6: ...edure bellow Press the fixing knob of the air intake grills the grilles will be opened wider and then pull them out from the indoor Remove the side panel fixing screw and pull to the front direction a...

Страница 7: ...bracket opening Refer to Fig 8 3 3 In Case of Hanging It is possible to install using inward facing hanger brackets by not removing the brackets from the indoor unit Refer to Fig 9 Be sure to use only...

Страница 8: ...e piping hole of the chassis and the bottom of the appliance upward then connect the live wire to the Terminal board L neutral wire to the Terminal board N and connect the earthing wire to the screw t...

Страница 9: ...wards at a gradient of at least 1 100 to prevent air pockets Refer to Fig 12 Use the attached drain hose and clamp Insert the drain hose completely into the drain socket Tighten the clamp within the r...

Страница 10: ...low static pressure fan Low static pressure L High static H Functional description of function dial up Dial up switch 1 S R Setting of memory mode including the standby mode and restoration mode The...

Страница 11: ...or units or slave indoor units shall be kept identical to its mode otherwise the system will give out mode conflict error Therefore when there are several master indoor units the address code of the u...

Страница 12: ...The dial up value of address code is set in binary system The dial up value is 0 when the lever is dialed to ON end the dial up is 1 when the lever is dialed to numerical end on opposite side For numb...

Страница 13: ...t setting The default Capacity dial up is the maximum capacity of indoor unit As shown above the capacity is See above for the lever position Dial up Value The dial up value of capacity code is set in...

Страница 14: ...KING TEMPERATURE RANGE Working Temperature Range Indoor side state Outdoor side state Dry bulb temp C Wet bulb temp C Dry bulb temp C Wet bulb temp C Rated Cooling 27 19 35 24 Max cooling 32 23 43 26...

Страница 15: ...te control with dry cloth or a vacuum cleaner If damp cloth is used remove moisture by using dry cloth afterward Caution Do not use benzene gasoline thinners or polishing products for cleaning Do not...

Страница 16: ...r close glass windows when cooling to prevent heat load from sun light which may cause more electricity cost To distribute cool air throughout the room adjust airflow direction as shown by the arrows...

Страница 17: ...ause damage or personal injury Also pay special attention when children are around Do not channel the airflow directly at people especially infants aged persons or patients Turn off the air conditione...

Страница 18: ...r the change of temperature The air conditioner cannot run Is power cut Is the power supply connected Is the circuit protector started aside Is the voltage too high or too low If TIMER had been set in...

Страница 19: ...y of unit and contact service center for the conditioner Harsh sound heard when running The fuse or protector cut frequently Substance or water pulled in the unit involuntary Water leakage in room Ove...

Страница 20: ...66129907087...

Отзывы: