– 25 –
TROUBLESHOOTING GUIDE
DISPLAY OF ERRORS IN THE PAST
Hold switch for more
than 10 seconds
Another push
Three beeps
The latest error indication
Another push
Another push
Another push
Four beeps
Three beeps
Two beeps
One beeps
The second latest error indication
The fourth error indication
The third latest error indication
Indication lamp goes off
ELECTRIC CHARACTER
〔
table 1
〕
Sensor, temp. room
〔
table 2
〕
Sensor, temp. defrost
Sensor, temp. outdoor
Sensor, temp. heat exchanger
〔
table 3
〕
Sensor, temp. discharge
〔
table 4
〕
Sensor, temp. power module
•
Push emergency operation switch and hold for more than 10 seconds while unit is not operated and release
the switch when you hear three beeps.
You will see the latest error by indication lamp.
Further pushing of the switch will make the error indication by reversing cycle up to four latest errors in the past.
At any stage, the error indication will disappear after 30 seconds.
47
37
29
23
18
15
Resistance (k
Ω
)
10
15
20
25
30
35
Temp. (
℃
)
Resistance (k
Ω
)
0
5
10
15
20
25
30
35
Temp. (
℃
)
31
24
19
15
12
10
8
7
1,000
600
300
250
160
50
Resistance (k
Ω
)
10
20
35
40
50
80
Temp. (
℃
)
201
80
35
17
9
5
Resistance (k
Ω
)
10
30
50
70
90
110
Temp. (
℃
)
TAN/TAG-A53EWI
Содержание TAG-A28EWI
Страница 32: ...31 ELECTRIC CIRCUIT DIAGRAM TAN A28EWI TAN A32EWI...
Страница 33: ...32 ELECTRIC CIRCUIT DIAGRAM TAN A53EWI...
Страница 34: ...33 ELECTRIC CIRCUIT DIAGRAM TAG A28EWI TAG A32EWI...
Страница 35: ...34 ELECTRIC CIRCUIT DIAGRAM TAG A53EWI...
Страница 44: ...ISSUED JUL 2004 RA 24 1 Printed in Japan...