– 24 –
TROUBLESHOOTING GUIDE
PCB(TAG main)
15
16
DC12V±2V
+
+
−
DC22V±3V
7
−
(1)
(1)
(7)
(8)
PCB(TAG main)
15
7
16
−
+
+
−
(1)
(1)
(7)
(8)
over 1kΩ
over 1kΩ
〔
fig. 8
〕
Voltage of Power module
〔
fig. 9
〕
Resistance of PCB(TAG main)
CHECK A FOLLOWING STEPS
Both power module
and PCB (TAG main)
are normal
Measure both voltages as follows
without taking off the connectors.
between 7 in the 15 and 1
in the 16 approx. DC 12V
±
2V
between 6 in the 16 and 7
approx. DC 22V
±
3V
METHOD OF CHECK
DC current detection and in case of irregular work of compressor
check the damage of piping, excess gas
check the resistance of power module
[see fig.7]
[see fig.8]
[see fig.9]
normal
accident of compressor
accident of PCB(TAG main)
accident of power module
take off the connectors 15 & 16
normal
normal
NO
NO
YES
YES
accident of power module
check the voltage (230V) between
1 and 2 in terminal of TAG, and
check the voltage of power module
check the voltage (230V) between
1 and 2 in terminal of TAG, and
check the voltage of power module
NO
YES
Flow Chart
TAN/TAG-A53EWI
Measure both resistances as follows
after taking off the connectors.
between 7 in the 16 and 1 in the
15 approx. over 1k
Ω
between 6
in the 15 and 7 approx. over 1k
Ω
PCB(TAG main) is normal.
Содержание TAG-A28EWI
Страница 32: ...31 ELECTRIC CIRCUIT DIAGRAM TAN A28EWI TAN A32EWI...
Страница 33: ...32 ELECTRIC CIRCUIT DIAGRAM TAN A53EWI...
Страница 34: ...33 ELECTRIC CIRCUIT DIAGRAM TAG A28EWI TAG A32EWI...
Страница 35: ...34 ELECTRIC CIRCUIT DIAGRAM TAG A53EWI...
Страница 44: ...ISSUED JUL 2004 RA 24 1 Printed in Japan...