background image

7. TRANSPORTATION

Preferably keep the unit in the vertical position during trans-
portation. If this is not possible then lay it on its rear side, when
at destination put the unit back in the vertical position and wait
at least ten (10) minutes before using it. Before
transporting/moving the unit make sure the drain tank is empty.

8. TROUBLESHOOTING

BEFORE CALLING FOR SERVICE

The followings are not defects.

9. SPECIFICATIONS

NOTE: Cooling air capacity will vary according to temperature

and humidity of the room.

10.VENTING KIT ACCESSORIES

If the unit is to be used exclusively in one space, the cooling ef-
ficiency will be enhanced by using the following venting kit ac-
cessories.

EXHAUST DUCT SET (FLEXIBLE TUBE) (Fig. I)

Max. 4 ft. (1.2m)

WINDOW PANEL KIT (Fig. J)

For sliding and double-hung
windows
Max. 37 in. (94cm)
Min. 28-1/4 in. (72cm)

USING EXHAUST DUCT SET (Fig. I)

1.

Insert both ends of exhaust duct hose (flexible tube) (I2) in-
to exhaust duct hose adapter nozzle (I1) by turning it
counter clockwise onto the tube and fix one of the exhaust
dust hose adapter nozzle (I1) into exhaust outlet (B3) by
turning it clockwise until it locks.

2.

Extend the exhaust duct hose (I2) and close the window or
door as far as possible trapping the exhaust duct hose
adapter nozzle (I1).

NOTE:

Place the unit as close as possible to the window
or door.

USING WINDOW PANEL KIT (Fig. J)

NOTE:

Window installations are possible by the use of
the exhaust duct set and window planel kit.

1.

Fix the exhaust duct hose grill (J3) to the window panel
with four (4) screws. Make sure that the panel is extended
so that screws do not go into sliding portion of panel.

2.

Open the window.

3.

Place the window panel in the window, extending it to fit
the width of the window. Once panel is extended, the pan-
el can be locked into this width by tightening the two (2)
screws on the top panel.

4.

Close the window.

5.

Attach the exhaust duct hose adapter nozzle (I1) on the ex-
haust duct hose grille (J3).

6.

When not in use, the exhaust duct hose adapter nozzle (I1)
may be closed off with the cover for exhaust duct hose
grille (J3) provided.

NOTE:

The same procedure can be adapted for vertical
installation in sliding windows.

3

ENGLISH

MODEL

TAD-30K

COOLING CAPACITY

10,000 BTU/H

DEHUMIDIFYING CAPACITY

0.42 gal/h (1.6 L/H)

POWER SOURCE

Single Phase 115V, 60Hz

POWER CONSUMPTION

1200 W

OPERATING CURRENT

9.5 A

AIR FLOW (MAX.)

177 CFM (300 m

3

/h)

OPERATING TEMP. RANGE

64˚F~95˚F (18˚C~35˚C)

DIMENSIONS (WxHxD)

17-1/8" x 30-1/4" x 17"

(435 x 770 x 430 mm)

WEIGHT

66 Lbs. (30 kg)

COMPRESSOR

ROTARY

REFRIGERANT

R-410A

SYMPTOM

Unit does
not work.

Unit sud-
denly stops
during in
operation.

Unit runs in-
termittently.

Unit func-
tions but the
room is not
cooled.

Condensed
water is
spilled out
when mov-
ing the unit.

CAUSE

- Power cut.

- The plug has been

plugged improperly.

- The full-tank indicator

is ON. Tank is full.

- The indoor tempera-

ture has reached the
set temperature level.

- The preset time is up.
- The full-tank indicator

is ON. Tank is full.

- Malfunction.
- Surrounding temper-

ature is too high or
too low.

- Exhaust duct hose is

blocked.

- Window or door is

left open in the room.

- There is heat source

in the room or too
many of people in it.

- Air intake grille is

clogged.

- Filter is too dirty.
- Temperature setting

is too high.

- The tank is nearly full.

SOLUTION

- Wait for power to be

supplied again.

- Plug in again.

- Remove the drain

water from the drain
tank.

- Reset the tempera-

ture level.

- Reset the timer.
- Remove the drain

water from the drain
tank.

- Contact your dealer.

- Check the duct hose.

- Close all windows

and door.

- Move out any heat

source in the room.

- Clean the air intake

grille.

- Replace the filter.
- Lower the tempera-

ture setting.

- Remove the drain

plug on the rear bot-
tom of the unit, drain
off the water then the
unit will be in opera-
tion automatically.

A hissing noise or hollow
sound :

A squeaking noise :

Odor :

The unit does not start nor
change operation mode
immediately :

e

This sound is generated from
the refrigerant flowing within
pipes.

e

This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.

e

Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.

e

To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.

  TAD-30K  (GB/ES/FR)    10.3.8  2:44  PM    ページ 3

www.sylvane.com  1-800-934-9194

Содержание TAD-30K

Страница 1: ...IONER ACONDICIONADOR DE AIRE PORTATIL CONDITIONNEUR D AIR DEPLACABLE INSTRUCTION MANUAL ENGLISH P 1 MANUAL DE INSTRUCCIONES ESPA OL P 5 MODE D EMPLOI FRANCAIS P 9 TAD 30K GB ES FR 10 3 8 2 44 PM b www...

Страница 2: ...B6 B5 A1 A3 A7 A5 A6 A4 A2 C1 C2 C7 C8 C9 C6 C3 C5 C4 C11 C12 C13 C10 more than 20 in 50cm more than 20 in 50cm F1 F2 J3 J5 J2 J1 J4 2 1 68 C13 C1 C5 C5 C3 C15 C2 C4 P TAD 30K GB ES FR 10 3 8 2 44 PM...

Страница 3: ...y Caster Float Micro switch Drain motor Blade Compressor Rear fan motor Rear fan Capacitor C Front FM Front fan motor Front fan Capacitor A Rear FM Main circuit board CapacitorB Compressor Indication...

Страница 4: ...mp yellow C10 Room temp lamp C11 Set temp lamp C12 Timer set lamp C13 Digital indicator C14 Signal receptor C15 C F toggle button Remote control Fig I EXHAUST DUCT SET I1 Exhaust duct hose adapter noz...

Страница 5: ...4 to select number of hours until you would like the unit to automati cally start USING REMOTE CONTROL The functions work the same as your air conditioner s op eration panel Fig C Batteries Remove the...

Страница 6: ...exhaust duct hose grille J3 provided NOTE The same procedure can be adapted for vertical installation in sliding windows 3 ENGLISH MODEL TAD 30K COOLING CAPACITY 10 000 BTU H DEHUMIDIFYING CAPACITY 0...

Страница 7: ...s to your nearest authorized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of TOYOTOMI w...

Страница 8: ...dvertencia Tanque lleno C7 Bot n del deflector de aire verde C8 Luz de modalidad seca anaranjado C9 Luz de la modalidad de enfriamiento amarillo C10 Luz de temperatura interior C11 Luz de temperatura...

Страница 9: ...prima el bot n selector C5 de velocidad del ventilador para ajustar al r gimen de flujo de aire deseado HI alto Funciona a un flujo de aire alto MED medio Funciona a un flujo de aire medio LO bajo Fun...

Страница 10: ...J NOTA Es posible la instalaci n en ventanas utilizando el juego de conducto de evacuaci n y el kit del panel de la ventana 7 ESPA OL Silbido o ruido sordo Chirrido Olores La unidad no arranca ni cam...

Страница 11: ...a fuerte cortocircuito etc instalaci n incorrecta o reparaci n por personal ajeno al establecimiento de servicio especificado por TOYOTOMI Titularidad El comprador original al detalle Alcance TOYOTOMI...

Страница 12: ...ventilation C4 Voyant de minuterie C5 Boutons de r glage C6 Lampe de avertissement R servoir plein C7 Bouton de d flecteur d air Orange C8 Lampe de mode sec Janne C9 Voyant de mode de refroidissement...

Страница 13: ...un affichage Celsius et Fahrenheit Lorsque vous utilisez la t l commande veuillez appuyer sur le bou ton de s lection C F T l commande C15 4 APPUYEZ SUR LE BOUTON DE SELECTION DE VITESSE DUVENTILATEU...

Страница 14: ...dispositif aussi pr s que possible de la fen tre ou de la porte 11 FRANCAIS Un bruit de sifflement ou un son creux Un bruit de grincement Odeur L unit ne d marre pas ou ne change pas de mode de fonct...

Страница 15: ...s et accessoires non autoris s ou non conformes aux normes TOYOTOMI mau vais fonctionnement lectrique c est dire r sultant de surtensions importantes courts circuits etc installation in correcte ou r...

Страница 16: ...I M M Printed in China New 3 10 Part No 22740795 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp TAD 30K GB ES FR 10 3 8 2 44 PM a www sylvane com 1 800 934 9194...