57
MAINTENANCE
Mid. Cooling/heating
(capability test code)
Cooling level AA
performance test
P3
/
Quick
ÀDVK
/
P3
P3
Level AA cooling
performance test
/
/
Quick
ÀDVK
P3
Phase over-current
protection
Compressor over-
current protection
P5
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Drive board
communication error(for
the commercial unit)
Communication error
between the inverter driver
to the main controller
P6
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Short/open circuit
of the of the module
temperature sensor
Short/open circuit
of the of the module
temperature sensor
P7
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Module temperature
protection
Module temperature
protection
P8
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
AC contact protection
(for the commercial unit)
AC contact protection
P9
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Circuit sensor error
Circuit sensor error
Pc
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Transducer connection
protection (for the
commercial unit)
Transducer connection
protection
Pd
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
AC current
protection(input side)
AC current
protection(input side)
PA
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Temperature drift
protection (for the
commercial unit)
Temperature drift protection
PE
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Drive board ambient
temperature sensor error
(for the commercial unit)
Drive board ambient
temperature sensor error
PF
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
DC link high voltage
protection
DC link low voltage
protection
PL
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
DC link low voltage
protection
DC link high voltage
protection
PH
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
/
Abnormal AC input voltage
PP
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Capacitor charging error
Capacitor charging error
PU
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Jumper terminal
error protection
Jumper terminal
error protection
C5
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Defrosting or oil
returning in heating
Defrosting or oil
returning in heating
H1
/
/
Flash
once
H1
Defrosting
symbol
displayed
/
Forcible defrosting
H1
Quick
ÀDVK
/
/
H1
H1
Compressor thermal
overload protection.
Compressor overload
protection.
H3
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Modulecurrent protection
(namely
IPM protection)
IPM Module current
protection
H5
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Compressor
desynchronizing
Compressor desynchronizing
H7
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
PFC Protection
PFC Protection
HC
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Too high power protection
(available for the
residential outdoor unit)
Too high power protection
(available for the
residential outdoor unit)
L9
Flash 20
times
/
/
oE
oE
Compressor startup failure
Compressor startup failure
Lc
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Compressor phase failure/
reverse protection
Compressor phase failure/
reverse protection
Ld
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Compressor rotation
failure(for the
commercial unit)
Compressor rotation
failure(for the
commercial unit)
LE
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Over speed (for the
commercial unit)
Over speed
LF
Flash 3
times
Flash 3
times
Flash 3
times
oE
oE
Short/open circuit of the
temperature sensor at the
inlet of the condenser coil
( for the commercial unit)
/
A5
/
/
/
/
/
Short/open circuit of
the temperature sensor
at the outlet of the
condenser coil ( for
the commercial unit)
/
A7
/
/
/
/
/
Memory card error
/
EE
/
/
/
/
/
Содержание MUL12- FWCA
Страница 1: ...Service Manual MODEL MUL FWCA Series...
Страница 4: ...1 PRODUCT...
Страница 11: ...11 CONTROL CONTROL...
Страница 30: ...54 MAINTENANCE...
Страница 41: ...66 MAINTENANCE 3 2 Indoor unit 3 2 2 Cassette type MUL12 FWCA MUL18 FWCA MUL24FWCA...
Страница 44: ...91 MAINTENANCE 5 2 2 Cassette type MUL12 FWCA...
Страница 46: ...93 MAINTENANCE MUL18 FWCA...
Страница 48: ...95 MAINTENANCE MUL24 FWCA...