![Toyotomi MUL12- FWCA Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/toyotomi/mul12-fwca/mul12-fwca_service-manual_1143430029.webp)
29
CONTROL
3.2.3 Guide for Optional Operation
ƹ
About BLOW
This function indicates that moisture in the evaporator of the indoor unit will be dried after the unit is stopped to
avoid mould.
a. BLOW ON: When press the ON/OFF button to turn off the unit, the indoor fan will continue running for about
another 10 minutes at the low speed. In this case, the indoor fan can be stopped directly by pressing the button BLOW.
b. BLOW OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped completely.
ƹ
About AFTERHEAT BLOW
Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop
running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor fan will
still run at the low fan speed. Then, 10 seconds later, the unit will stop completely.
ƹ
About AUTO RUN
When AUTO RUN is selected, the setting temperature will not be displayed on the LCD and the unit will choose
the suitable running mode automatically in accordance with the room temperature.
ƹ
About TURBO
If this function is activated, the unit will run at super-high fan speed to cool or heat quickly so that the ambient
temperature will approaches the preset temperature as soon as possible.
Содержание MUL12- FWCA
Страница 1: ...Service Manual MODEL MUL FWCA Series...
Страница 4: ...1 PRODUCT...
Страница 11: ...11 CONTROL CONTROL...
Страница 30: ...54 MAINTENANCE...
Страница 41: ...66 MAINTENANCE 3 2 Indoor unit 3 2 2 Cassette type MUL12 FWCA MUL18 FWCA MUL24FWCA...
Страница 44: ...91 MAINTENANCE 5 2 2 Cassette type MUL12 FWCA...
Страница 46: ...93 MAINTENANCE MUL18 FWCA...
Страница 48: ...95 MAINTENANCE MUL24 FWCA...