TROUBLESHOOTING

Should problems arise during operation or ignition, use this chart to determine the cause and 
the proper steps to take. Be sure to unplug heater and allow to cool completely before taking 
corrective measures.

PROBLEM

CAUSE

SOLUTION

POWER LAMP FAILS
TO TURN ON

—Disconnected power plug
—Incorrect wiring
—Circuit board malfunction

—Plug into 230V AC outlet.
—Consult your dealer.
—Consult your dealer.

NO IGNITION

—Out of fuel
—Clogged air filter
—Use of inferior kerosene

(paraffin)

—Incorrect wiring
— Circuit board, ignition heater 

or fuel pump malfunction

—Refuel
—Clean air filter.
— Remove fuel and refuel using 

fresh, clear kerosene (paraffin).

—Consult your dealer.
—Consult your dealer.

ODOR

—Clogged air filter
—Spilled kerosene (paraffin)

—Use of inferior kerosene

(paraffin)

—Clean air filter
— Wipe off any kerosene (paraffin) 

spills from fuel sub tank, remov-
able fuel tank and drip tray.

— Remove fuel and refuel using 

fresh, water-clear kerosene 
(paraffin).

EXTINGUISHED
AFTER IGNITION

—Excessive room temperature
—Oxygen shortage in room

—Tip-over switch activated
— Water in fuel acceptance 

fitting

—Out of fuel
— Flame sensor or fuel pump 

malfunction

—High limit switch activated

—Allow room to cool.
— Open doors and windows to 

ventilate room thoroughly.

—Reignite.
— Remove fuel and refuel using 

fresh, water-clear kerosene 
(paraffin).

—Refuel
—Consult your dealer.

— Clean circulation fan cover, 

remove any obstructions.

POOR COMBUSTION/
NOISY COMBUSTION

—Clogged air filter
— Loose screws or incorrect 

assembly

—Incorrect wiring
— Circuit board or fuel pump 

malfunction

—Altitude too high

—Clean air filter.
—Consult your dealer.

—Consult your dealer.
—Consult your dealer.

—Consult your dealer.

If the corrective measures outlined above do not solve the problem, please consult your dealer.

Содержание LC-44

Страница 1: ...44 IMPORTANT READ AND UNDERSTAND INSTRUCTIONS BEFORE USING HEATER RETAIN INSTRUCTIONS FOR FUTURE REFERENCE CONTENTS SPECIFICATIONS 1 PART NAME 1 OPERATION 5 EMERGENCY MESSAGE 11 ROUTINE MAINTENANCE 12...

Страница 2: ...ated is influenced by so many factors it is impossible to specify a heater output to an exact room size If you use a heater too large for the area to be heated the temperature you desire will be reach...

Страница 3: ...constant The operation is in Save mode operation Ventilation Indicator flashing Oxygen level in room is insufficient Heater shuts off automatically Fuel Indicator constant Fuel tank empty Only 10 min...

Страница 4: ...packing materials for future storage of your heater 4 When positioning your heater for use keep it away from walls and all other materials as illustrated below 50cm 150 cm 50 cm 20 cm 150 cm 5 The fl...

Страница 5: ...he pump turn anti clockwise once the gauge indicates that the tank is full Never overfill the tank especially not when the fuel is very cold fuel expands when it heats up NOTE Be careful to avoid over...

Страница 6: ...es after switching off the heater the information on the display will disappear and the heater will automatically switch into the stand by position IGNITION 1 Just press the key to ignite the heater T...

Страница 7: ...cator will return to Clock mode displaying the present time 3 Your heater will now automatically start up the pre set time 4 If you wish to start up the heater at the pre set time again repeat the sam...

Страница 8: ...E Room temperature measurements are taken directly behind the heater These measurements may not represent the true room temperature 1 2 SAVE OPERATION The SAVE function allows you to limit the tempera...

Страница 9: ...continues blinking after extra ventilation please contact your dealer FUEL INDICATOR When the Fuel Indicator lights up it means that there is only fuel left for 10 more minutes The count down of the...

Страница 10: ...HEATER While heater is burning press power switch to OFF position This will extinguish heater and ON OFF Lamp on the indicator panel will go out The circulation fan motor will operate further for app...

Страница 11: ...the altitude mode 1 is set the altitude mark is lit on the display When the altitude mode 2 is set the altitude mark is blinking during operation NOTE In the event of power failure or disconnection of...

Страница 12: ...te after inserting the plug again e 5 You have accidentaly activated your safety tip over switch You should reset this device as described press the OFF button and restart your heater e 6 Burner flame...

Страница 13: ...Never wipe with cloth it will clog filters further 2 Clean Fan Cover Using a vacuum cleaner remove any dust from the fan cover at the back of the heater 3 Clean Fuel Acceptance Fitting When dirt or du...

Страница 14: ...lean air filter Wipe off any kerosene paraffin spills from fuel sub tank remov able fuel tank and drip tray Remove fuel and refuel using fresh water clear kerosene paraffin EXTINGUISHED AFTER IGNITION...

Страница 15: ...2 Clean Heater Wipe off any dirt or dust on heater with a damp cloth then wipe again using a dry cloth 3 If your heater needs any service or repair now is the time to call your dealer to have it done...

Страница 16: ...Printed in Japan 4879001921 New 08 18...

Отзывы: