8.
Secure the L-shaped hose to the intake inlet mouth with the hose band. Secure the bent joint to the
standard flue pipe with the pipe holder (If the extension pipe is used, also attach the pipe holder to the
connection of the bent joint and the extension pipe). Secure the bent joint (or the extension pipe) to the
exhaust outlet mouth by sliding the pipe stopper into the exhaust mouth bracket (See Fig. 12).
9.
Make sure the position of the heater is level by using the plumb bob located at the right side of the
heater. The plumb bob weight should be within the circle. If the plumb bob weight is not within the cir-
cle, adjust the heater legs until the plumb bob weight is within the red circle (See Fig. 13 & 14).
26
Good
Bad
Plumb bob as viewed from above
Circle
Weight
Fig. 13
Fig. 12
Fig. 14
Pipe Stopper
Pipe Stopper
Pipe Holder
Good
Bad
Plumb bob as viewed from above
Circle
Weight
Содержание Laser 30