Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
83
Field
Meaning
9
Switch-off at total
The number of the total parts reached at
which the working process is ended and
a stored red message is issued on the
display.
10
Accept
The settings are applied.
The window will close.
Shift counter - Switch-off at OK
A limit value can be entered in the input field
Switch-off at OK
. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
Tapping on the
Reset
button resets the counter. After that, the next mea-
surement can be continued.
The value
0
deactivates the corresponding option. The system is not shut
down and no message is issued.
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
ü
Menu ''Lot size\Shift counter'' is open
1.
Tap on the
Switch-off at OK
input field.
w
The numerical keyboard opens.
2.
Enter the desired value and confirm with
↲
.
Value
0
deactivates the function.
Reset ''Switch-off at OK'' counter
1.
When the limit value in input field ''Switch-off at OK''has been reached:
2.
Reset the counter by tapping on the
Reset
button.
3.
Start process again.
Shift counter - Switch-off at total
A limit value can be entered in the input field
Switch-off at total
. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
The value
0
deactivates the corresponding option. The system is not shut
down and no message is issued.
Содержание CEP400T
Страница 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Страница 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 111: ...Repairs TOX_Manual_Process monitoring unit_CEP400T_en 111 11 Repairs 11 1 Repair work No repair work is necessary ...
Страница 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 115: ...Appendices TOX_Manual_Process monitoring unit_CEP400T_en 115 13 Appendices 13 1 Declaration of conformity ...
Страница 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 117: ......
Страница 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Страница 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...