Software
76
TOX_Manual_Process-monitoring-unit_CEP400T_en
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
ü
The ''Enter the Configuration -> Force sensor configuration\Nominal
force'' menu is opened.
1.
Move to the first point, e.g. press opened.
2.
Determine the applied force (e.g. by a reference sensor attached tem-
porarily to the press) and simultaneously if possible tap the
Teach 1
button for reading the applied force.
w
The applied electrical signal is read in.
3.
Tap on the
Force 1
display/input field.
w
The numerical keyboard opens.
4.
Enter the value of the measuring value of the electrical measuring sig-
nal to be displayed and confirm with
↲
.
5.
Move to the second point, e.g. closing the press with a certain press
force.
6.
Determine the currently applied force and simultaneously if possible tap
the
Teach 2
button for reading the applied force.
w
The current electrical measuring signal is accepted and displayed
in a new display/input field
Measuring value 2
next to the
Teach 2
button.
7.
Tap on the
Force 2
display/input field.
w
The numerical keyboard opens.
8.
Enter the value of the measuring value of the electrical measuring sig-
nal to be displayed and confirm with
↲
.
9.
Save the changes with
Accept calibration
.
u
When pressing the
Accept calibration
button the process monitoring
system calculates the parameters of nominal force and offset from the
the two force values and the measured electrical signals. That con-
cludes the calibration.
Содержание CEP400T
Страница 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Страница 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 111: ...Repairs TOX_Manual_Process monitoring unit_CEP400T_en 111 11 Repairs 11 1 Repair work No repair work is necessary ...
Страница 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 115: ...Appendices TOX_Manual_Process monitoring unit_CEP400T_en 115 13 Appendices 13 1 Declaration of conformity ...
Страница 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Страница 117: ......
Страница 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Страница 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...