100001021-50
Figure 53: Pilot assembly.
CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to
cool before servicing appliance. It is recommended that the fireplace and its venting
should be inspected at least once a year by a qualified service person.
Glass Panel:
Warning:
Do not operate fireplace with glass panel removed, cracked or broken.
Replacement of the glass panel should be done by a licensed or qualified service
person.
Do not strike or otherwise impact the glass in anyway that may cause it to break. If
the glass becomes cracked or broken it must be replaced before using the fireplace.
Replacement glass can be obtained from your nearest Town & Country Fireplaces
TM
dealer. The size required is 52" x 16" x 5mm. Use ceramic glass only. Do not substitute
with any other type.
To remove broken glass, remove window frame as noted in "Window Frame Removal"
section.
Unclip the Glass Retainer Clips located at the top and sides of the Window Frame. Pull
the top edge of the glass out of the frame first, then lift it up and out of the bottom edge.
Install the new piece of glass with the gasket into the frame so that the thicker bead of
gasket faces the fireplace.
Re-install glass retaining clips.
Annual Inspection:
a) Remove glass panel and pebble assemblies. Inspect pebble and burner assemblies for soot buildup. If excessive buildup of soot
is present, have a qualified service person inspect and adjust unit for proper combustion. Clean logs and burner with a brush or
vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper flame size and operation. Clean pilot free of soot, dust or any other deposits. (See Fig. #67)
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled for cleaning, it
must be properly assembled and re-sealed. Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.
b) Exterior finish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fireplace.
Do not clean glass when hot.
PILOT FLAME
FLAME SENSOR
ELECTRODE
PILOT
34
TCWS54D2 091418-40
Maintenance