5055.545-A
Figure 63: Orifices.
WARNING
This conversion kit shall be
installed by a qualified service
agency in accordance with the
manufacturer's instructions
and all applicable codes and
requirements of the authority
having jurisdiction.
If the information in these
instructions is not followed
exactly, a fire, explosion or
production of carbon monoxide
may result causing property
damage, personal injury or loss
of life.
The qualified service agency
is responsible for the proper
installation of this kit.
The installation is not proper and
complete until the operation of
the converted appliance is
checked as specified in the
manufacturer's instructions
supplied with the kit.
If the unit is to be used on propane convert as follows using the
components supplied with the burner:
CAUTION
The gas supply and electrical power shall be shut off before
proceeding with the conversion.
Note:
Factory supplied components must be used to ensure correct input. After conversion
confirm proper manifold pressure.
1.
If installed remove the sand and
rocks from the burners.
2.
If installed remove the burner
tray. (8 screws) (Figure 64).
3.
Remove burners by gently lifting
up the end and disengaging from
the orifice.
4.
Remove access panel beneath
the burners in order to remove
the gas valve motor head
stepper motor. (See SIT conver-
sion kit instruction book for
complete conversion
instructions).
5.
Using a 1/2” wrench, undo the
natural gas burner orifice,
(marked #32).
Apply a small amount of pipe
joint compound to the threads
of the propane burner orifice
(marked #51) to ensure a good
seal, before screwing it into the
manifold.
Loosen the primary air shutter
screw, open shutter to give a gap
of 13/64” (0.2”) and re-tighten.
Repeat on other burner (Figure
66)
6.
With a 7/16” wrench loosen the
pilot head on the pilot assembly.
(Figure 67)
MAIN BURNER
1.78mm ORIFICES
P/N (5022.72)
Propane Conversion
Figure 64: Burner tray.
ORIFICES
Figure 65: Orifice Removal.
Gap
Figure 66: Primary air shutter.
Pilot head
Figure 67: Pilot assembly.
32