Roof Vent Terminal:
1. Place the roof flashing over the vent pipe, secure and seal it to the roof using the
methods and materials appropriate for the type of roof on the building. Shingle roof
example shown (Fig #39).
2. Place the storm collar down over the vent pipe until it is level. Tighten storm collar for
a snug fit. Apply a thick horizontal ring of mastic around the pipe at top of the storm
collar. (Fig #39)
3. Lower the roof vent terminal cap over the vent pipe and secure in place with screws
provided. (Fig #39) Seal screw heads and joint with caulking to prevent any moisture
entering the venting system.
VERTICAL TERMINATION CAP
(TCVT.9365)
FLASHING
STORM COLLAR
(TC42.90665)
MASTIC
NOTE: ADJUSTABLE FOR VARIOUS ROOF
PITCHES, FROM FLAT ROOF TO 12/12 PITCH
ROOF.
VENT PIPE
Fig. #39