5.5.7 MAGNETIC SCALE DESCRIPTION
5.5.8 READ HEAD SIZE AND INSTALLATION INSTRUCTIONS
P08
Concentric circle
diameter
0.01~9999.99
500.00
The diameter of a disk
attached to a magnetic strip
The diameter needs to be added
to the thickness of the magnetic
strip:1.5mm*2=3mm
P09
Angular resolution
0.01°
0.01’
0.05’
0.1’
1°
0.01°
Angle pattern effectiveness
After modification,Press the
confirmation key:
P10
Second sets
to measured
values,offset setting
0-----999999
0
Offset 1 2 3
Please press the combination key:
+
Offset the offset value
P11
Absolute /relative
mode
0:open
1:lock
0
After modification,Press the
confirmation key:
P12
Origin value setting 0-----999999
0
The value of the input will be
saved as the original point
value
After modification,Press the
confirmation key:
P20
Restore factory
settings
77777
77777
Restore the default factory
settings
Password validation needs to be
entered before recovery:1234
Magnetic scale consists of 3 parts.:total thickness of the three layer is1.8mm,width of10mm, The length of 50m roll packing.
A: Soft magnetic ruler
B: Non magnetic steel
C: This layer is A soft magnetic scale protection strip(as shown in the figure)
Magnetic paste:The thin tape must be adhered to clean
、
dry
、
a flat surface.Is a typical cleaning
agent 50% alcohol or 50% mixture of water or heptane (Please note that on exposure to this solvent manufacturer)
.
in copper
、
yellow
metal surface should ensure that no clean surface oxide layer
.
1:Read heads and magnetic scale spacing between 1mm----2mm control
2:Install the read head, read head logo, press the arrow pointing in the direction of alignment of magnetic ruler
3:Read head installation angle deviation requirements(see figure)
Standard pitch induction head and tape: 1mm