Operation System
Automatic flushing for this product operates as shown below.
This product has the following automatic flushing functions.
<Interval discharge pipe flush>
In addition to flushing after every use, discharge pipe flushing is performed every 2 hours. Performing discharge
pipe flushing over several flushes and efficiently flushing reduces urine accumulation and urolith adhesion inside the
discharge pipe.
<"e-water+" cleaning> * e-water+ type only
Time periods when the urinal is not used for a long time, such as at night, are judged automatically and the trap is
filled periodically with "e-water+". Because the occurrence of dirt inside the trap is reduced, the flush volume after
use can be reduced.
* "e-water+" is water created by electrolyzing chloride ions contained in tap water, and includes sanitizing components
(hypochlorous acid).
CAUTION
The above effects cannot be obtained while the power supply is off.
* In the AC or e-water+ types, water is flushed when the power supply recovers after a power outage. This is
normal.
Pre-flush setting method
Set switch No. 1 on the controller to " ON ".
Do not apply excessive force to the switch.
After setting, return the controller to its
original installation condition.
Switches and settings
Switch No.
Setting
OFF
(initial state)
ON
Approx. change in water
volume used when
OFF→ON
1
Pre-flush
No
Yes
+0.3 L/flush
2
Interval discharge pipe flush
Yes
No
-24 L/day
* When interval discharge pipe flush is set to off
(switch No. 2 set to " ON "), the effect of reducing
urolith adhesion is no longer obtained.
Although the Auto Flush Wall Mounted Urinal (Compact) is effective in reducing urolith adhesion, it does not remove
urolith that has already adhered. (The frequency of periodic flushing is reduced, but does not become unnecessary.)
Interval discharge pipe flushing is performed automatically every 2 hours.
Keep the power supplied 24-hours a day.
Pre-flush Setting
* When the product is shipped, pre-flush is set to " OFF ". Change the setting as required.
Detection
•
A person
approaching the
urinal is detected
by the sensor.
Pre-flush
•
The urinal is
flushed before use.
CAUTION
•
The setting
described on
Page 7 must be
configured to
activate the pre-
flush.
•
The urinal is flushed
automatically every
2 hours to reduce
urolith adhesion on
the urinal trap and
discharge pipe.
•
Discharges water
6 times a day at
times of infrequent
use. This reduces
urolith adhesion
on the trap of the
urinal.
Main flush
•
After use, the urinal
is flushed when the
person moves away
from the urinal.
•
Urinals with manual
flush buttons can also
be flushed by pressing
the button on the right
side of the unit.
Interval discharge
pipe flush
"e-water+" cleaning
*e-water+ type only
Manual
flush button
Every 2 hours
Switches
Controller
Controller
Switches
If the controller does not slide out on its own,
use a flat-head screwdriver to lower it.
6
7
Op
e
ra
tio
n