background image

Operation System

Automatic flushing for this product operates as shown below.

This product has the following automatic flushing functions.

<Interval discharge pipe flush>

In addition to flushing after every use, discharge pipe flushing is performed every 2 hours. Performing discharge 
pipe flushing over several flushes and efficiently flushing reduces urine accumulation and urolith adhesion inside the 
discharge pipe.

<"e-water+" cleaning> * e-water+ type only

Time periods when the urinal is not used for a long time, such as at night, are judged automatically and the trap is 
filled periodically with "e-water+". Because the occurrence of dirt inside the trap is reduced, the flush volume after 
use can be reduced.

* "e-water+" is water created by electrolyzing chloride ions contained in tap water, and includes sanitizing components 

(hypochlorous acid).

CAUTION

The above effects cannot be obtained while the power supply is off.

* In the AC or e-water+ types, water is flushed when the power supply recovers after a power outage. This is 

normal.

Pre-flush setting method

Set switch No. 1 on the controller to " ON ".

Do not apply excessive force to the switch.

After setting, return the controller to its 
original installation condition.

Switches and settings

Switch No.

Setting

OFF

 (initial state)

ON

Approx. change in water 

volume used when

OFF→ON

1

Pre-flush

No

Yes

+0.3 L/flush

2

Interval discharge pipe flush

Yes

No

-24 L/day

* When interval discharge pipe flush is set to off 

(switch No. 2 set to " ON "), the effect of reducing 
urolith adhesion is no longer obtained.

Although the Auto Flush Wall Mounted Urinal (Compact) is effective in reducing urolith adhesion, it does not remove 
urolith that has already adhered. (The frequency of periodic flushing is reduced, but does not become unnecessary.)

Interval discharge pipe flushing is performed automatically every 2 hours.
Keep the power supplied 24-hours a day.

Pre-flush Setting

* When the product is shipped, pre-flush is set to " OFF ". Change the setting as required.

Detection

 

A person 
approaching the 
urinal is detected 
by the sensor.

Pre-flush

 

The urinal is 
flushed before use.

CAUTION

 

The setting 
described on 
Page 7 must be 
configured to 
activate the pre-
flush.

 

The urinal is flushed 
automatically every 
2 hours to reduce 
urolith adhesion on 
the urinal trap and 
discharge pipe.

 

Discharges water 
6 times a day at 
times of infrequent 
use. This reduces 
urolith adhesion 
on the trap of the 
urinal.

Main flush

 

After use, the urinal 
is flushed when the 
person moves away 
from the urinal.

 

Urinals with manual 
flush buttons can also 
be flushed by pressing 
the button on the right 
side of the unit.

Interval discharge 

pipe flush

"e-water+" cleaning
*e-water+ type only

Manual 
flush button

Every 2 hours

Switches

Controller

Controller

Switches

If the controller does not slide out on its own, 
use a flat-head screwdriver to lower it.

6

7

Op
e

ra

tio

n

Содержание USWN925 Series

Страница 1: ...safe place for future reference Instruction Manual Table of Contents Safety Precautions 2 Part Names 5 Operation System 6 Pre flush Setting 7 Routine Maintenance 8 Periodic Inspection 11 Replacing the...

Страница 2: ...oller during thunderstorms Doing so may cause electrical shock Wet hands prohibited Do not plug or unplug the connector with wet hands Doing so may cause electrical shock WARNING Do not disassemble Do...

Страница 3: ...the floor with a well wrung mop or cloth Leaving such substances on the floor may cause staining or corrosion Wipe off any condensation from the surface of the urinal or other parts with a dry cloth F...

Страница 4: ...Pre flush No Yes 0 3 L flush 2 Interval discharge pipe flush Yes No 24 L day When interval discharge pipe flush is set to off switch No 2 set to ON the effect of reducing urolith adhesion is no longe...

Страница 5: ...ts may cover the porcelain surface and reduce the effect of the built in stain prevention technology Place a towel etc over the photoelectric sensor Photoelectric sensor stops detecting Remove the tow...

Страница 6: ...or with a well wrung mop or cloth Wipe any urine that splashes out from the urinal or condensation that drops from the apparatus onto the floor with a well wrung mop or cloth Wipe any detergent or wat...

Страница 7: ...ry replacement method continued Remove the battery box then remove the waterproof cover Place the battery box inside the controller Remove the spent alkaline battery replace the battery then attach th...

Страница 8: ...attery type Replace the battery P 12 Flushed water does not stop Close the shutoff valve and contact your installer or seller P 16 Flushed water volume is low Dirt is clogging the water filter Clean t...

Страница 9: ...shing performance may drop and impair hygiene Detection LED lights up or flashes In the AC type alkaline battery type and e water types the sensor detection LED may light up or flash When the LED ligh...

Страница 10: ...rce When dirty scrub using a toilet brush etc with a neutral toilet detergent Water flushes on its own This product has the following automatic flushing functions Interval discharge pipe flush In addi...

Страница 11: ...s within 650 mm of the sensor Required detection time About 5 seconds or longer not detected when less than 5 seconds Water supply pressure Minimum required water pressure dynamic 0 07 MPa Maximum wat...

Отзывы: