Specifications

Type

Wall-mounted

AC

e-water+

Alkaline battery

Part No.

USWN925AE

USWN925AEP

USWN925AS

USWN925ASP

USWN925A

Dimensions

W 306 mm × D 400 mm × H 590 mm

Power supply

AC220-240 V

50 Hz / 60 Hz

Battery type

Power consumption and

battery life

0.5 W or less

0.5 W or less

e-water+

24 W during discharge

4,000 times/month

About 2 years

Operating ambient

temperature range

0~40°C

Detection distance

Automatically adjusted to 650 mm or less

* Installation not possible if a wall is within 650 mm of the sensor

Required detection time

About 5 seconds or longer (not detected when less than 5 seconds)

Water supply pressure

Minimum required water pressure (dynamic): 0.07 MPa

Maximum water pressure (static): 0.75 MPa

Standard flush volume

During use

0.5 L

Pre-flush function

Can be set to "OFF" (setting at shipment) or "0.3 L/flush"

Interval

discharge pipe flush

2 L every 2 hours

* Automatically adjusted according to usage

* Except USWN925AEP/ASP

e-water+

No

0.5 L each time

* 6 times/day

No

Water supply connection

15A (connection screw PJ1/2)

Used water

Tap water   Recycled water

*1

*1 When using recycled water, there may be cases where e-water+ will have no effect.

20

21

R

e

fe

renc

e

Содержание USWN925 Series

Страница 1: ...safe place for future reference Instruction Manual Table of Contents Safety Precautions 2 Part Names 5 Operation System 6 Pre flush Setting 7 Routine Maintenance 8 Periodic Inspection 11 Replacing the...

Страница 2: ...oller during thunderstorms Doing so may cause electrical shock Wet hands prohibited Do not plug or unplug the connector with wet hands Doing so may cause electrical shock WARNING Do not disassemble Do...

Страница 3: ...the floor with a well wrung mop or cloth Leaving such substances on the floor may cause staining or corrosion Wipe off any condensation from the surface of the urinal or other parts with a dry cloth F...

Страница 4: ...Pre flush No Yes 0 3 L flush 2 Interval discharge pipe flush Yes No 24 L day When interval discharge pipe flush is set to off switch No 2 set to ON the effect of reducing urolith adhesion is no longe...

Страница 5: ...ts may cover the porcelain surface and reduce the effect of the built in stain prevention technology Place a towel etc over the photoelectric sensor Photoelectric sensor stops detecting Remove the tow...

Страница 6: ...or with a well wrung mop or cloth Wipe any urine that splashes out from the urinal or condensation that drops from the apparatus onto the floor with a well wrung mop or cloth Wipe any detergent or wat...

Страница 7: ...ry replacement method continued Remove the battery box then remove the waterproof cover Place the battery box inside the controller Remove the spent alkaline battery replace the battery then attach th...

Страница 8: ...attery type Replace the battery P 12 Flushed water does not stop Close the shutoff valve and contact your installer or seller P 16 Flushed water volume is low Dirt is clogging the water filter Clean t...

Страница 9: ...shing performance may drop and impair hygiene Detection LED lights up or flashes In the AC type alkaline battery type and e water types the sensor detection LED may light up or flash When the LED ligh...

Страница 10: ...rce When dirty scrub using a toilet brush etc with a neutral toilet detergent Water flushes on its own This product has the following automatic flushing functions Interval discharge pipe flush In addi...

Страница 11: ...s within 650 mm of the sensor Required detection time About 5 seconds or longer not detected when less than 5 seconds Water supply pressure Minimum required water pressure dynamic 0 07 MPa Maximum wat...

Отзывы: