![Kohler CABERNET WATER-GUARD K-3401 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/kohler/cabernet-water-guard-k-3401/cabernet-water-guard-k-3401_installation-instructions-manual_1989931001.webp)
112037-2-
AA
(A)
1998 Kohler Co.
CABERNET
WATER-GUARD
VITREOUS CHINA
SIPHON VORTEX TOILET
K-3401, K-3408
BEFORE YOU BEGIN
HOW TO USE THESE INSTRUCTIONS
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your partic-
ular installation. This will help you avoid costly mistakes.
In addition to proper installation, read all operating and
safety instructions.
All information in these instructions is based upon the lat-
est product information available at the time of publica-
tion. Kohler Co. reserves the right to make changes in
product characteristics, packaging, or availability at any
time without notice.
These instructions contain important care, cleaning, and
warranty information – please leave instructions for the
consumer.
ORDERING INFORMATION
Cabernet
Water Guard
Toilet (round)
K-3401
. . . . . .
Seat
K-4662
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabernet
Water Guard
Toilet (elongated)
K-3408
. .
Seat
K-4653
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When specified:
Floor bolts (pair)
21401
. . . . . . . . . . . . . . . . . . . . . . . .
NOTES
Seat post holes on 5-1/2” centers.
Water depth from rim is 6-3/4”.
2-1/4” passageway.
Ensure that the new toilet has the correct
roughing-in dimension. The K-3401 and K-3408
have a 12” roughing-in dimension. See Fig. #1.
Closet flange must be 12” on-center from wall.
Carefully inspect the new fixture for any sign of
damage.
Observe all local plumbing and building codes.
Shut off the water supply.
For new construction, refer to the dimensions in
Fig. #1 and Fig. #4 for locating the shut-off valve.
Fixture dimensions are nominal and conform to
tolerances established by ANSI Standards
(A112.19.2).
Toilet must be installed with a 1/2” shut-off valve.
25 p.s.i. running pressure is required at the
shut-off valve.
WARNING: Risk of personal injury or product
damage: Handle vitreous china products very
carefully. Vitreous china can break and chip if you
overtighten bolts and nuts.
TOOLS AND MATERIALS REQUIRED
10” adjustable wrench
12” pipe wrench
Metal file (file cut)
Tape measure
Tubing cutter
Level
Hacksaw
Putty knife
Screwdriver
Toilet gasket (wax seal)
Toilet T-bolts (2), 5/16” diameter
NOTICE: If the existing toilet does not have a supply
shut-off valve below the tank, install one before installing
the new toilet.