Toto T112 Скачать руководство пользователя страница 10

Notes

10

Flange

Prepared hole (

φ

4) 

for coach screw

Prepared hole (

φ

4) 

for coach screw

Plywood, 

etc.

Cover

Washer

120 or less

Cover

Cover

Washer

Reinforcing 

wooden block

Paper honeycomb

Decorative 

plywood sheet

30 or more

Prepared hole 

(

φ

4) for hanger bolt

Prepared hole 

(

φ

4) for hanger 

bolt

Reinforcing 

wooden block

30 or more

Paper honeycomb

Decorative 

plywood sheet

Nut

Washer

Nut

<Wooden base>

<Toilet booth>

9 to 16

9 to 16

120 or less

Plywood, 

etc.

Prepared hole (

φ

4) 

for coach screw

Washer

Flange

Flange

Flange

Reinforcing 

wooden 

block

Plywood, etc.

Cover

Cover

Washer

Prepared hole 

(

φ

4) for hanger 

bolt

Reinforcing 

wooden 

block

Cover

Washer

Nut

9 to 16

Plywood, etc.

Screw 2 nuts and turn the nuts to the different 
directions each other to tighten and fix. 

Coach screw

Hanger bolt

Intermediate 

support part

 Mount reinforcing wooden blocks on the 

handrail mounting area beforehand.

 Carry out centering and then make prepared 

holes of 

φ

4 mm for hanger bolts.

(In the case of a tile wall, make through holes 
of 

φ

6.5 mm only in the tile area.)

 Fix using the nuts (2 pieces) as a double nut, 

which come with the hanger bolts. 

Note 1

 Turn the double nut fixed in 

 using a tool, and screw the hanger bolt into the prepared hole 

in the intermediate support part of the handrail.

 Adjust the projecting length of the bolts to be between 9 and 16 mm from the finished wall 

surface.

 Remove the double nuts.

 Put the hanger bolt through the mounting hole of the flange in the intermediate support part 

of the handrail, and then temporarily tighten with the washer and nut.

 Put the coach screws through the washers and attach to the wall through the mounting hole 

of the flange.

 Fully tighten the nut that is temporarily tightening the hanger bolt.

 Press the cover against the finished surface. 

Note 2

Finished wall surface

Finished wall surface

Finished wall surface

Finished wall surface

Finished wall surface

Finished wall surface

(Unit: mm)

Flange

Flange

Wooden base, Toilet booth: Fixing with coach screws and a hanger bolt

7

-3

. Installing the Handrail

Fixing bracket part number

Wooden base: T110D15, T110D16, T110D34
Toilet booth: T110D23, T110D35

Target product

Thickness of plywood sheet

or reinforcing wooden block

30 mm or more

60 mm or more

Versatile handrail  I type

Versatile handrail  L type

Handrail for sitting toilet  L type

(T112CL11

CL12,

 T113BL11

BL12)

Handrail for sitting toilet  P type

Handrail for Japanese-style toilet

Handrail for urinal

Handrail for wall-mounted washbasin

12 mm or more

L type handrail for sitting 
toilet
(T112CL10,T113BL10)

I type handrail for washing 
area in bathroom

Note 2: Adjust the projecting length of the hanger bolts to be between 9 and 16 mm 

from the finished wall surface. 

For the intermediate support parts of the versatile L type handrail and the L type handrail for 
sitting toilet (front protrusion dimension: 120 mm), use hanger bolts that facilitate installation.

As the versatile I type handrail does not use hanger bolts, its installation procedure is 

and 

.  

Note 1: The thickness of the reinforcing wooden blocks differs depending on the type 

of handrail. Give reinforcement appropriate for the handrail.

Mount a reinforcing plywood sheet or wooden blocks with a thickness that conforms 
to the table below securely on a strong pillar, etc. If reinforcing wooden blocks are 
not mounted, the handrail may have backlash or come off.  

*Only when the front protrusion dimension 

of the handrail is 120 mm or less.

*Mount a structural plywood sheet (JAS 

standard product) or an equivalent or 

better one to the base material. 

Содержание T112

Страница 1: ... T O designa t e d No backlash Do not install the product outdoor or in areas that might be submerged Doing so could cause a user to fall due to the damage or coming off of the handrail and may result in injury Make sure that the base has sufficient thickness and is reinforced and install the handrail by the specified installation method If the base does not have sufficient thickness or is not rei...

Страница 2: ...ch Use the outer bolt holes M6 55 Resin pipe φ13 Fixing with hanger bolts Fixing position 1 position Hanger bolt 4 pieces Washer and nut 4 pieces each M6 11 φ6 L Hanger bolt T110D34 L 50 T110D35 L 30 Unit mm 2 2 Before Installation About the resin coating type grip bar Shape Part No Details of the set Name Fixing bracket list Unit mm Shape Part No Details of the set T110D41 T110D11 T110D62 T110D42...

Страница 3: ... 2 3 4 7 6 5 8 9 10 shows the parts that need to be procured in the field Pipe indicates metal pipes φ13 8 t2 Please purchase them at a hardware store or a home improvement center Prepare pipes with an appropriate length considering the thickness of the wall means that it cannot be installed Note 1 GL method Available only when the thickness of GL Gypsum Lining is 50 mm or less Note 2 Concrete blo...

Страница 4: ...7 3 T110D46 3 T110D37 3 T110D46 3 T110D36 1 T110D46 2 T110D3R 1 T110D36 1 T110D46 2 T110D37 2 T110D46 2 T110D36 2 T110D46 4 T110D36 1 T110D46 2 T110D3R 1 T110D36 1 T110D37 1 T110D46 3 T110D11 2 T110D41 2 T110D11 3 T110D41 3 T110D11 3 T110D41 3 T110D11 3 T110D41 3 T110D62 1 T110D41 2 T110D3R 1 T110D62 1 T110D41 2 T110D11 2 T110D41 2 T110D62 2 T110D41 4 T110D62 1 T110D41 2 T110D3R 1 T110D11 1 T110D6...

Страница 5: ...ling a bathtub WARNING 550 700 L Resin coating T112CP21 T112CP22 Stainless steel T113BP21 T113BP22 Weight Weight 2 5kg 2 9kg 2 4kg 2 7kg 550 700 L Resin coating T112CP26 T112CP27 Weight 1 6kg 2 1kg φ34 Wall surface φ86 L 150 φ34 Wall surface Floor surface φ86 φ 85 φ 84 φ 85 L 250 150 550 700 A In the case of T113BL10 the cover for the corner part is φ84 In the case of T113BL11 12 the cover for the...

Страница 6: ...assemble the handrail are in the packing box Only for handrails to be assembled Fixing brackets for installing the handrail on the wall floor are optional parts Check the connection method of the connection part When using bolts Assembling the Handrail 6 See P 7 Finishing the Connection Part See P 15 Inspection Items See P 15 Mounting the handrail When there is no connection part in the completion...

Страница 7: ... the grip bars to each other with a hexagonal wrench Push the washer large into the joint and then push the grip bar into the joint Attach the washer large in such a way that its flat surface comes into contact with the grip bar Attach the bolts in the same procedure as that of part A in Completion Drawing 4 Because a washer has a flat surface and a curved surface place the flat surface on the spr...

Страница 8: ...d wall surface Put the continuous thread studs through the mounting holes of the flange and then tighten with the washers and nuts Press the cover against the finished surface Note 2 Notes 3 and 4 Note 4 Note 1 7 1 Installing the Handrail Finished wall surface Finished wall surface Concrete 50 or more 37 or more Anchor bolt Mortar Nut Nut Mounting plate Washer Washer Cover Flange 9 to 16 Anchor bo...

Страница 9: ...or more 9 to 16 Prepared hole φ8 Resin plug Hanger bolt Hanger bolt Flange Nut Washer Finished wall surface Nut 120 or less 120 or less 9 to 16 Cover Cover Flange Cover Finished wall surface Finished wall surface 60 or more 120 or less Flange Washer Prepared hole φ8 Prepared hole φ8 Resin plug Coach screw Cover Resin plug Coach screw Mortar Mortar Concrete Mortar Concrete Flange Washer 60 or more ...

Страница 10: ... the nut that is temporarily tightening the hanger bolt Press the cover against the finished surface Note 2 Finished wall surface Finished wall surface Finished wall surface Finished wall surface Finished wall surface Finished wall surface Unit mm Flange Flange Wooden base Toilet booth Fixing with coach screws and a hanger bolt 7 3 Installing the Handrail Fixing bracket part number Wooden base T11...

Страница 11: ... side After finishing the wall adjust the projecting length of the continuous thread studs to be between 9 and 16 mm from the finished wall surface Put the continuous thread studs through the mounting holes of the flange and then tighten with the washers and nuts Press the cover against the finished surface Note 3 Unit mm Finished wall surface 9 to 16 125 or less Concrete block Mortar Mounting pla...

Страница 12: ...les of the flange and then tighten with the washers and nuts Press the cover against the finished surface While carrying out centering fix the mounting plate to the reinforcing light gauge steel frame t 2 3 mm or more by welding Screw the continuous thread studs into the holes of the mounting plate adjust their projecting length to be between 9 and 16 mm from the finished wall surface and tighten ...

Страница 13: ...th drilling screws After finishing the wall carry out handrail centering and make φ12 mm through holes for mechanical nuts Insert the mechanical nuts into the through holes and set them Put the bolts through the washers and attach to the wall through the mounting holes of the flange Press the cover against the finished surface Note 1 Note 3 In the handrail mounting position fix the mounting bracke...

Страница 14: ... holes Check the bolt holes before installation Put the bolts through the mounting holes of the flange and then tighten with the washers and nuts Press the cover against the finished surface Note 1 Note 1 Prepared hole guide for fixing bracket T110D22R Do not use the inner holes because they are the mounting hole positions for the handrail T114 type Mounting hole positions outer holes of the handr...

Страница 15: ...struction manual to the customer After installing the handrail fully tighten the bolt with a hexagonal wrench Attach the cap Cap Bolt Claw Claw Claw orientation Claw orientation 8 Finishing the Connection Part When Using Bolts 9 Inspection Items See 6 Assembling the Handrail See 8 Finishing the Connection Part See 7 Installing the Handrail Since the cap has a predetermined orientation attach it in...

Страница 16: ...e position Handrail mounting hole position Cover Cover φ65 φ65 φ65 C u t h e r e C u t h e r e Cut here Be sure to confirm that the prepared hole positions of the product match the handrail mounting hole positions of the guide before making prepared holes When you copy this sheet and use the copy the size of the illustration may change depending on the printing machine Please check the dimensions ...

Отзывы: