4. DEHUMIDIFICATION PROCESS
Our drying cabinet relies on a drying agent to control humidity lev-
els. This drying agent will be rejuvenated (recycled) for ½ hour in
every 6 hours. Its drying agent is completely recyclable and there is
no required maintenance. During the recycling period, absorbed
moisture will be discharged through the external shutter. After recy-
cling, the shutter will close and moisture inside dry cabinet will once
again be absorbed by the refreshed drying agent. This dehumidifica-
tion cycle will continue until the set humidity point is achieved. Once
the humidity level exceeds the setting level, this dehumidification
cycle will start again.
Every drying cabinet has contact switches installed on each of the doors to control a fan inside the
electric drying unit. The interlocked fan operates for about 2 hours after the drying agent is rejuve-
nated in order to accelerate moisture absorption. The interlock fan stops when the door is opened to
minimize inflow of ambient air into the unit. The interlock fan will operate for 20 minutes when the
doors are closed to speed up moisture absorption inside the drying cabinet.
5. INSTALLATION
Do not operate the drying cabinet near the shutter of air-conditioners, places with high temperature,
smoke and dust or a place with direct sunshine. Please use an extra metal plate, if necessary, to
place the drying cabinet in a stable place to avoid any instability for the glass doors.
6. PARTS of the DRYING CABINET