Totech Super Dry ESDA Series Скачать руководство пользователя страница 2

 

 

 

 

CONTENT

 

 

1.   SAFETY GUIDANCE 
2.   APPLICATIONS 

3.   SUPERIOR FEATURES OF DRYING 

4.   DEHUMIDIFICATION PROCESS  
5.   INSTALLATION 

6.   PARTS OF DRYING CABINET  
7.   ADJUSTMENTS 

8.   CALIBRATION 
9.   TROUBLE SHOOTING 

10. OPTIONS 
11. CE - DECLARATION 

 

1. SAFETY GUIDANCE 

Please read this SAFETY GUIDANCE carefully to avoid any possible danger of electric shock or damage 
to the drying cabinet due to improper use. 
 

Unplug the drying cabinet if there is any smoke or smell coming from it. 
Do not try to repair the electric drying unit. To do so could void your warranty 

 

Unplug the drying cabinet in case of  spilled liquid inside it.  
It may cause electric shock. 

 

Do not disassemble or reconfigure the electric drying unit. 

It may cause electric shock. 

 
 

 

Do not put flammable or explosive materials inside the drying cabinet. 

It may cause electric shock. 

 

Do not operate the drying cabinet in a damp or wet environment. 
It may cause electric shock. 

 

Do not damage, twist, pull or place anything heavy on the power cord. 
It may cause electric shock. 

 

 

Do not block off the shutter. Always keep the electric drying unit upright. Do not 

place the unit sideways  or upside down. It may cause fire or damages. 
 
Do not plug or unplug the drying cabinet  with a wet hand. Make sure to plug it 

properly. 
It may cause electric shock. 
 
Do not stand on or place anything heavy on the drying cabinet. 

There is an extreme tipping danger. 
 
Do not put any flammable or volatile liquids such as ether, benzene, LP gas or alcohol 

etc inside the drying cabinet. It may cause explosion. 
 

Do not place any hydrochloric acid, sulfuric acid or other corrosive chemicals in the 
drying cabinet . It may cause corrosion. 
 

The glass doors of the drying cabinet may shatter under impact. 

 

 

Содержание Super Dry ESDA Series

Страница 1: ... you for purchasing our dry cabinet In order to use the drying cabinet properly and safer please read this INSTRUCTION MANUAL care fully and consult our representatives for any questions Please keep this INSTRUCTION MANUAL carefully for future reference ...

Страница 2: ...ve materials inside the drying cabinet It may cause electric shock Do not operate the drying cabinet in a damp or wet environment It may cause electric shock Do not damage twist pull or place anything heavy on the power cord It may cause electric shock Do not block off the shutter Always keep the electric drying unit upright Do not place the unit sideways or upside down It may cause fire or damage...

Страница 3: ...y Dehumidification After recycling the drying agent by heat the interlocked fan inside the electric drying unit starts to operate for about 2 hours to accelerate the moisture absorption 2 Exception Recovery Times The interlocked fan tops operating when the door is open to ensure minimal inflow of outside am bient air Once the doors are closed this fan starts operating again to accelerate the moist...

Страница 4: ...on cycle will start again Every drying cabinet has contact switches installed on each of the doors to control a fan inside the electric drying unit The interlocked fan operates for about 2 hours after the drying agent is rejuve nated in order to accelerate moisture absorption The interlock fan stops when the door is opened to minimize inflow of ambient air into the unit The interlock fan will oper...

Страница 5: ...Y This TEMPERATURE DISPLAY LIGHT will switch off after 5 seconds automatically and the dis play will show the current internal humidity level 5 Setting the humidity alarm The HUMIDITY ALARM LIGHT will be on if the internal RH level exceeds the setting point Press both DOWN and SET button at the same time to set the humidity alarm function When the display is flashing adjust the humidity setting po...

Страница 6: ...n on the display again 7 Setting the time of N2 Auto Purge System provided as option Press both H T and DOWN button at the same time to set the rinsing time When the display is flashing adjust the activated time in minutes for the N2 Auto Purge System by pressing either UP or DOWN button The initial setting is 10 minutes Press the SET button again when you finish setting the internal humidity leve...

Страница 7: ...ED display 4 Press the SET button to start the calibration the current offset value on the LED display will begin to flash To end the calibration program and start the operation of SUPER DRY press the ON OFF twice 5 Adjust the humidity offset point with the UP or DOWN button UP increases DOWN decreases the offset value After finishing adjustments press the SET button again The new offset value wil...

Страница 8: ...erials are very damp The humidity level will not rise above the ambient humidity level if the drying cabinet is not equipped with humidification capability Please refer to the following instructions in case of any replacement of the electric drying unit or PCB Replacement of the Electronic Drying Unit 1 Remove the power plug 2 Remove the CONTROL BOX by loosening 4 screws 3 Detach the connector JP6...

Страница 9: ...90 x 517 1152 x 1690 x 517 material casing and door made from conductive acrylic glass PMMA in aluminum profile frame weight 48kg 92kg dehumidifier U 2000 for 1 RH average energy consumption 31W maximum energy consumption 290W input supply voltage 230V 50Hz 120V 60 HZ max shelf bearing load 30kg number of shelves 5 10 Environmental Conditions Temperature 5 C bis 40 C Altitude up to 2000m Relative ...

Страница 10: ...ounds when the internal RH level exceeds its setting point Casters and Anchoring Legs are available for flexible movement of effective stabiliza tion Door Alarm Buzzer sounds when the door is left open for a certain period of time standard SD SDB not deliverable Wrist Strap Connection allows you to ground yourself prior to handling ESD sensitive inventory Available for all SD Series drying cabinet...

Страница 11: ...2 PJ Dronten confirm that the drying cabinet described corresponds with the fundamental safety and health de mands of the following EC instructions EN55011 1998 A1 1999 A2 2002 EN61000 6 2 2001 2006 95 EG 2004 108 EG Totech Europe B V Gerhard Kurpiela technical director ...

Отзывы: