About Advanced Features & Operation
Page 18
M
ICRO
P
ULSE
Technology Vs. Conventional Control - Advanced
Setup Step # 9 allows the
I
NTELLI
S
TAT
to be configured to
control the
I
NTELLI
M
IST
Humidifier or a conventional Humidifier.
M
ICRO
P
ULSE
Technology equipped controls for humidifiers
are intelligent controls that take into account various parameters
which include: HVAC equipment size, outdoor temperature,
indoor temperature, heat or fan operation and whether the
equipment is a Heat Pump or not.
The above information is used to calculate the amount of
moisture the air will carry efficiently without saturating the inside
of your duct work.
An
I
NTELLI
M
IST
humidifier will be ‘pulsed’ on and off with varying
durations and intervals based on the above settings.
If the humidifier used with this control is not an
I
NTELLI
M
IST
Step # 9 should be OFF.
Conventional Humidity Control will provide a continuous
signal to the humidifier as long as there is a humidity
demand and a call for heating or the fan is energized.
To control a conventional humidifier, Step # 9
in the Advanced Setup Section should be set to OFF.
MEMORY BACKUP - In the event of a power loss, the
will retain the stored program settings without
external power or batteries.
I
NTELLI
S
TAT
MINIMUM HEAT/COOL SETPOINT DIFFERENCE - The Heat
and Cool setpoints will not be allowed to come any closer
to each other than the value set in Advanced Setup
step
# 7, on page 14
. This minimum difference is enforced
during Auto changeover
operation.
and Program On