Advanced Setup
Page 14
Continued
Select
I
NTELLI
M
IST
(
ON
)
M
ICRO
P
ULSE
Control,
or conventional humidity
control (
OFF
).
Adjust the MicroPulse
interval for the size
HVAC equipment by
Tonnage.
Select
ON
for ‘Standalone’
Humidity/Fan operation.
Inteillistat will turn on
the fan and humidifier
with a humidity demand,
or,
Select
OFF
to only
turn on the humidifier
if in Heat or Fan and there
is a humidity demand.
I0
I I
Setup
Setup
Ton
7
8
9
Setup
Pls
3
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Adjust the minimum
difference
between
cooling & heating
setpoints.
(0 - 6 )
Setup
2
81f
Select the cycles per
hour limit.
d=cycles per hour
limit defeated.
d1=d + defeat 5 min.
Compressor lockout.
(d, d1, 2 - 6)
cy
Setup
6
ON
ON
Humidity
(1 - 7)
On
On
Off
Off
Step 10 only appears if Step 9 is On
Heat
Cool