1-11
Functions of the
µ
FLO
Functions of the
µ
FLO reflect a design that is practical, straight-forward and efficient. The
µ
FLO is
simple to use and easy to learn - and it saves time usually spent on calculations and report preparation.
The
µ
FLO allows you to perform the following with minimum effort, maximum speed and greater
accuracy.
Complete log period flow and operational records reported (hourly, default) including -
•
Average static pressure
•
Average differential pressure
•
Average flowing temperature
•
Corrected volume total
•
Corrected energy total
•
Operating status and alarms
Complete daily flow records including -
•
Average static pressure
•
Average differential pressure
•
Average flowing temperature
•
Average Extension
•
Corrected volume total
•
Corrected energy total
•
Operating status and alarms
Complete daily operation statistics including -
•
Percent flowing time
•
Percent back flow time
•
Percent out of limits (programmable) on SP, DP, Tf and Flow Rate
•
Minimum and maximum values for SP, DP, Tf and Flow Rate
µ
FLO
Capabilities
The records and statistics generated are due to the following capabilities of the
µ
FLO:
•
Calculation of flow rates, volume and coefficients per AGA-3, AGA-8
Supercompressibility standards
•
Calculation of flow extension
Tf
Sp
Dp
*
once per second
•
Extrapolation of flow accumulation during IMV calibration
•
Selection of all coefficients for calculation; calculation of dynamic factors
(dependent upon DP, SP and Tf) using averages based on one second
samples
•
Sample set of most recent calculations allowing subsequent verification
•
Monitoring of the operational limits, minimums and maximums to insure
detection and reporting of malfunctions or abnormal site conditions
•
Acceptance and storage of system constants from the PCCU or remote
communications protocols.
•
Storage of data records and operational events determined by user (based on
available SRAM)
Continued on Next Page
Содержание uFLO
Страница 1: ...2100890 001 AB TOTALFLOW µFLO Computer User s Manual ...
Страница 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 8: ...vi B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 14: ...xii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 16: ...1 2 FLO 6213 Figure 1 1 µFLO 6213 Dimensions ...
Страница 17: ...1 3 4 186 3 141 4 355 9 359 3 23 12 602 8 647 9 992 9 367 13 206 Figure 1 2 µFLO 6210 Dimensions ...
Страница 18: ...1 4 Figure 1 3 Bottom View µFLO 6213 9 367 9 992 8 647 Figure 1 4 Bottom View µFLO 6210 ...
Страница 39: ...2 9 FLO 6213 Figure 2 7 µFLO 6213 Wall Mounted ...
Страница 41: ...2 11 SOLAR PANEL 5 VALVE INSTRUMENT MANIFOLD ORIFICE 6213 FLO Figure 2 8 µFLO 6213 Direct Mounted ...
Страница 50: ...2 20 Figure 2 13 Mounting AC Charger ...
Страница 60: ...3 10 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 62: ...3 12 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 64: ...3 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Страница 70: ...4 6 11 9 5 4 1 13 3 FLO 6210 12 8 7 10 2 Figure 4 2 µFLO 6210 Component Cable Locations ...
Страница 71: ...4 7 1 6 FLO 6213 5 13 3 2 4 7 8 10 9 12 11 Figure 4 3 µFLO 6213 Component Cable Locations ...
Страница 132: ...6 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...