Installation

Use the following procedures to install the Bus Conversion Unit in a QP-Ethernet 
Series unit.

1. Disconnect the QP-Ethernet Series

power cord from the power supply.

2. Remove the three (3) Expansion

Slot covers on the rear of the
QP-Ethernet Series unit.

• Do not remove this Unit from the QP-Ethernet unless absolutely necessary. 

Excessive attachment and removal can lead to the Unit's premature 
breakdown or malfunction.

Rear of Bus Conversion Unit Rear of QP

Expansion

Slot covers

Copper
spring
contact
location

Copper Spring

Prior to installing this Unit:
• When attaching this unit to the QP-Ethernet Series units, make sure that 

the QP-Ethernet's power cord is not plugged in to the main power (constant), 
to prevent an electric shock.

• Be careful not to touch the surface of this unit's printed circuit board and be

sure to wear cotton gloves.

WARNINGS

CAUTIONS

• Do not touch the "copper spring" or the copper spring's contact. Be sure to wear

gloves when installing this unit.

Содержание QPI-PSL-201

Страница 1: ...Bus Conversion Unit 10 5 12 1 QuickPanel Ethernet Series Installation Guide Bus Conversion Installation Guide GFK 2073 ...

Страница 2: ...ly on an as is basis In no event shall Total Control Products Inc be liable to anyone for special collateral incidental or consequential damages in connection with or arising out of purchase or use of these materials The sole and exclusive liability to Total Control Products Inc regardless of the form of action shall not exceed the purchase price of the materials described herein No part of this m...

Страница 3: ...5 and 12 1 QP Ethernet Series units This manual provides an overview of this Unit as well as procedures to follow when installing it in the User s system Be sure to read all this important information carefully prior to using this Unit This product is CE marked and UL c UL CSA compliant Therefore be aware that when it is used in combination with a product that is not CE marked and UL c UL CSA comp...

Страница 4: ...re the Unit is operated in an environment that is within the unit s desig nated temperature range Do not operate or store this unit in an environment where it will be exposed to high temperatures Do not operate or store this unit in an environment where it will be exposed to direct sunlight or excessive amounts of dust Since this unit is a precision instrument do not install it where strong impact...

Страница 5: ...ng methods Article 501 4 b of the National Electrical Code NFPA 70 within the United States and in accordance with Section 18 152 of the Canadian Electrical Code for units installed within Canada 2 Suitable for use in Class I Division 2 Groups A B C and D Hazardous Loca tions 3 WARNING Explosion hazard substitution of components may impair suitability for Class I Division 2 4 WARNING Explosion haz...

Страница 6: ...ntion to quality However should you find anything damaged or missing please contact your local distributor immediately Package Contents Bus Conversion Unit QPI PSL 201 Bus Conversion Unit Installation Guide 1 this document Bus Conversion Unit Installation Guide Attachment Screws 4 Top The Unit s external dimensions are given below 1 Dimensions Unit mm in Front Right Side 32 1 26 223 8 78 136 5 35 ...

Страница 7: ...gures below show the Bus Conversion Unit and an expansion unit attached to a 10 5 or 12 1 QP Ethernet Series unit Unit mm in Rear Top Left Side 89 3 50 31 1 26 136 5 35 85 3 35 227 8 94 223 8 78 301 11 85 8 0 31 ...

Страница 8: ...age Temperature 20 o C to 60 o C Humidity 10 RH to 90 RH no condensation Vibration based on JIS B 3501 IEC61131 2 Resistance intermittentvibration 10Hz to 57Hz 0 075mm 57Hz to 150Hz 9 8m s2 continuous vibration 10Hz to 57Hz 0 035mm 57Hz to 150Hz 4 9m s2 X Y and Z directions for 10 times each 80min Corrosive Gas Free ofcorrosive gas External Dimensions W223 8 78 x H136 5 35 x D32 1 26 mm in Main un...

Страница 9: ... Unit s premature breakdown or malfunction Rear of Bus Conversion Unit Rear of QP Expansion Slot covers Copper spring contact location Copper Spring Prior to installing this Unit When attaching this unit to the QP Ethernet Series units make sure that the QP Ethernet s power cord is not plugged in to the main power constant to prevent an electric shock Be careful not to touch the surface of this un...

Страница 10: ...the screws Be sure that no gaps remain between the QP Ethernet Series unit and the Unit 6 Attach the expansion unit to the Bus Con version unit and tighten the two 2 ex pansion unit attachment screws included with unit Attachment Screw Holes Attachment Screws Attachment Tabs Expansion Unit Users Manual A torque of only 0 5 to 0 6 N m is required to tighten an attachment screw Be careful not to use...

Отзывы: