3-6
MP/8 V.34: Getting Started
No Flow Control Template
—
&F0
This template does not include features such as a fixed serial
port rate or hardware flow control. Table 3.4 on the opposite
page lists all the configuration settings with differences from the
default template noted in bold.
Recommended Uses
This is good for low-performance situations. It offers
compatibility with non-typical computers, older equipment, or
software that cannot handle flow control and other features.
Note:
If DIP switch 10 is ON when the modem is powered on,
or you load factory template 0 (&F0), the following settings take
effect.
Table 3.3
&F0 No Flow Control Low PerformanceTemplate
Options
Setting Description
Handshake option
B0
ITU-T answer sequence
Normal/error control
&M4
Normal/error control
Data compression
&K1
Enabled
Transmit data flow control
&H0
Disabled
Rec'd data hardware flow control
&R1
Disabled
Rec'd data software flow control
&I0
Disabled
Serial port rate select
&B0
Detect from AT command:
variable rate
Link rate select
&N0
Variable
Result code subset
X1
Basic
Error-control response codes
&A1
Enabled
Tone/Pulse dialing
P
Pulse dial
Online local echo
F1
Disabled
Remote Digital Loopback (RDL)
&T5
Deny RDL
Normal/Leased
&L0
Normal phone line
Data Set Ready operations
&S0
Override enabled
Break handling
&Y1
Clear buffer, send immediately
Stored telephone number
&Z0
−
9=0
Blank
Pulse dial make/break ratio
&P0
U.S./Canada
Guard tone
&G0
U.S./Canada
Word length*
7
Parity*
1
Even
DTE rate* (bps)
9600
–