Disposal of Packing Materials
Cleaning
●
Whenever necessary, wipe the product with dry, clean, and soft cloth.
●
Refrain from directly applying water, thinner or other chemicals to the product. Those materials
may cause damages, discoloring, and distortion to the product.
●
Do not leave packing material at the installation site.
●
Separate combustible cardboard from noncombustible waste.
●
Observe the local waster separation regulations when disposing of the materials.
Product Specification
Rated Power Voltage
Rated Power Frequency
Power consumption
Operating voltage
Operating current
Power rating
Rated Current
Time rating
Ambient Temperature
AC 100 to 240V
50/60Hz
During stand by : 0.5W or lower , Max . load operation : 86W
DC24V
3 mA
0.86A (AC100V), 0.48A (AC240V)
8 min.(continuous operation)
0 to 50°C (non-condensing)
Progress Motor
25
50
0.59N.m
0.98N.m
P . 18
Curtain moves
automatically when
force opened
manually.
Moves adversely and
in opposite direction
Operation speed is
low
Movement speed after
having spent a power
supply is low
Operates only while
pushing the button
●
The rail is not assembled correctly.
⇒
Set up according to "About Motor Rotation Direction Switching" on page 12.
●
The switches and interior wiring are not connected correctly.
⇒
Exchange the red and green cables and reconnect.
●
The interior wiring and Modular outlet are not connected correctly.
⇒
Exchange the red and green cables and reconnect.
●
The various setting switch No.4 is turned ON.
⇒
Turn off the switch No.4.
●
Opening/closing is set to the slowest speed.
⇒
Refer to "Speed Setting Switch (sec./m)" on page 13 and change to a more suitable
speed.
●
The instruction has not been completed.
⇒
Refer to "Limit Setting Method" on page 14 and completely finish the Limit Setting Method
(instructive operation)
●
The Address Setting Switch is set to "F".
⇒
Set the Address Setting Switch to a number between 1 and 9.
●
The value set here corresponds to two-button operations.
⇒
Turn off the No.1 setting switch.
●
The various setting switch No.3 is turned on and Touch-motion functions is set.
⇒
Turn off the switch.
Troubleshooting
■
Before you decide that the trouble is a malfunction, perform the following check.
Not operating
Condition
Possible Causes and Solution
●
The power cord plug is not connected.
⇒
Switch the Progress Motor Set to on (AC 100–240V).
●
The wire from the switch is not connected to the Motor Set.
⇒
Refer to "Wiring Method" on page 6 and connect appropriately.
●
The Infra-red Receiver is not installed to enable remote control.
⇒
Refer to "Wiring Method" on page 6 and connect appropriately.
●
Address of motor set is not correctly set.
⇒
Refer to "Address Setting Switch'' on page 13 and set the address.
●
In case of FM remote control, wiring from receiver 2.4G with IR termnal is connected to "SW".
⇒
Connect to "IR".
●
In case of FM remote control, the receiver has no address setting.
⇒
Refer to Instruction manual of FM Receiver and set the address.
●
No connection is in place between the interior wiring and the switch or the modular outlet.
⇒
Refer to "Connection Method" on page 9 and connect appropriately.
●
In case of remote control, the battery is not in the FM transmitter.
⇒
Install batteries in the transmitter.
Unstable
operation
●
Batteries are old.
⇒
Replace old batteries with new batteries.
●
Inverter light is used near the Infra-red Receiver.
⇒
Remove the Infra-red receiver from the inverter light.
●
Infra-red Receiver is under the sun light.
⇒
Remove the Infra-red receiver to a location with no sun light.
●
There is an obstacle blocking the curtain.
⇒
Remove the obstacle before the curtain in the opening/closing position.
●
Connection between the interior wiring and the switch or the modular outlet is loose.
⇒
Refer to "Connection Method" on page 9 and connect appropriately.
P . 19