47
CONTROLS AND FEATURES
Engl
ish
Colour Calibration
The aim of Colour Calibration is to measure and/or adjust the
colour response (White Balance) of your LCD panel.
Colour Calibration is used by various fields, such as gaming,
photography, engineering, medical and more. In order to
calibrate a display correctly, you need a colour analyzer
TPA-1
(not supplied).
NOTE:
This feature is available when the Picture Mode option
is
Hollywood Pro
.
Apply Calibration
a
In the
Expert Picture Settings
menu, press
B
or
b
to
select
Colour Calibration
and press
OK
.
b
Press
B
or
b
to select
Apply Calibration
and press
C
or
c
to select
Enabled
.
Manual Colour Calibration
a
In the
Colour Calibration
menu, press
B
or
b
to
select
Manual Colour Calibration
and press
OK
.
b
Place the probe of the colour analyzer over the square
on screen to measure.
c
Input the value measured with the colour analyzer
using the number buttons (0-9).
d
Press
BbC
c
and input the values to fill all RGBxy
matrix table.
e
Highlight
Start
and press
OK
.
Please wait until you see “Manual Colour Calibration
has been completed.” on screen.
To return to factory setting
a
Highlight
Reset
and press
OK
.
Auto Colour Calibration
a
In the
Colour Calibration
menu, press
B
or
b
to
select
Auto Colour Calibration
and press
OK
.
b
Connect the USB colour analyzer to the USB 1 or USB
2 port.
c
Place the probe of the USB colour analyzer over the
square on screen and press
OK
.
Auto Colour Calibration
will start.
Please wait until you see “Auto Colour Calibration has
been completed.”.
Gamma Calibration
a
In the
Expert Picture Settings
menu, press
B
or
b
to
select
Gamma Calibration
and press
OK
.
b
Press
B
or
b
to select
Apply Calibration
and press
C
or
c
to select
Enabled
.
c
Press
B
or
b
to select
Auto Gamma Calibration
and
press
OK
.
d
Connect the USB colour analyzer to the USB 1 or USB
2 port.
e
Input the target value and place the USB colour
analyzer over the square on screen.
f
Highlight
Start
and press
OK
.
Auto Gamma Calibration will start.
Please wait until you see “Auto Gamma Calibration
has been completed.” on screen.
To return to factory setting
a
Highlight
Reset
and press
OK
.
Resetting to the factory defaults
a
In the
Expert Picture Settings
menu, press
B
or
b
to
select
Reset
and press
OK
.
A confirmation screen appears.
b
Select
Yes
and press
OK
.
Manual Colour Calibration
Red
0.642
x
y
0.277
0.143
0.335
0.603
0.067
Blue
Green
Start
Reset
Please input the value measured with the coulour analyser.
Red
0.642
x
y
0.277
0.143
0.335
0.603
0.067
Blue
Green
Auto Gamma Calibration
Target Colour Temperature
0.313
x
y
2.4
0.329
Target Gamma
Start
Reset
Please input the target value and place the USB colour analyser
over the square.
Содержание ZL1* Digital Series
Страница 1: ...ZL1 Digital Series ...