Adjustment range
0.0-3200 (s)
0.0-3200 (s)
0: Linear, 1: S-pattern 1, 2: S-pattern 2
0: Linear, 1: S-pattern 1, 2: S-pattern 2
1: Acc/dec 1, 2: Acc/dec 2, 3: Acc/dec 3
0.0- (Hz)
0-50 (%)
0-50 (%)
0.0-3200 (s)
0.0-3200 (s)
0: Linear, 1: S-pattern 1, 2: S-pattern 2
0.0- (Hz)
0- (Hz)
0-30 (Hz)
0- (Hz)
0-30 (Hz)
0- (Hz)
0-30 (Hz)
0: Reverse, 1: Slowdown Stop
0.5-10 (Hz)
0- (Hz)
0- (Hz)
0: Invalid, 0.1-600 (s)
0, 1, 2
List of parameters
- (Hz)
Title
Function
Adjustment range
Default setting
Preset-speed operation frequency 8
Preset-speed operation frequency 9
Preset-speed operation frequency 10
Preset-speed operation frequency 11
Preset-speed operation frequency 12
Preset-speed operation frequency 13
Preset-speed operation frequency 14
Preset-speed operation frequency 15 (Fire-speed)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
- (Hz)
- (Hz)
- (Hz)
- (Hz)
- (Hz)
-
(Hz)
- (Hz)
Title
Function
Adjustment range
Default setting
Dynamic braking selection
Dynamic braking resistance
Dynamic braking resistor capacity
0: Invalid, 1: Valid
1.0-1000 (
Ω
)
0.01-30.00 (kW)
0
* 1
* 1
* 1: Default values vary depending on the capacity.
Title
Function
Adjustment range
Default setting
Base frequency 2
Base frequency voltage 2
Torque boost value 2
Motor electronic-thermal protection level 2
Stall prevention level 2
25-500 (Hz)
50-330 (V)/50-660 (V)
0-30 (%)
10-100 (%/A)
10-199 (%/A), 200: Invalid
50/60
230/460/575
* 1
100
150
Title
Function
Adjustment range
Default setting
Acceleration time 2
Deceleration time 2
Acceleration/deceleration 1 pattern
Acceleration/deceleration 2 pattern
Acceleration/deceleration 1, 2, 3 selection
Acc/dec 1 and 2 switching frequency
S-pattern lower-limit adjustment amount
S-pattern upper-limit adjustment amount
Acceleration time 3
Deceleration time 3
Acceleration/deceleration 3 pattern
Acc/dec 2 and 3 switching frequency
10.0
10.0
0
0
1
0.0
10
10
10.0
10.0
0
0.0
Title
Function
Adjustment range
Default setting
Jog run frequency
Jog run stopping pattern
Panel jog run operation mode
- 20.0 (Hz)
0, 1, 2
0: Invalid, 1: Valid
5.0
0
0
Title
Function
Adjustment range
Default setting
Jump frequency 1
Jumping width 1
Jump frequency 2
Jumping width 2
Jump frequency 3
Jumping width 3
0- (Hz)
0-30 (Hz)
0- (Hz)
0-30 (Hz)
0- (Hz)
0-30 (Hz)
0.0
0.0
0.0
0.0
0.0
0.0
Title
Function
Adjustment range
Default setting
Priority selection (Both F-CC and R-CC are ON)
Starting frequency setting
Operation starting frequency
Operation starting frequency hysteresis
Time limit for lower-limit frequency operation
Reverse-run prohibition
1
0.5
0.0
0.0
0.1
0
0-2400 (s)
0: Invalid, 1: Valid
0.01-100.0
0.01-100.0
0.00-2.55
Title
Function
Adjustment range
Default setting
Logic output/pulse train output selection (OUT-NO)
Pulse train output function selection (OUT-NO)
Maximum numbers of pulse train
Inclination characteristic of analog output
Meter bias
0: Logic output, 1: Pulse train output
0-17 (Same as
)
500-1600(PPS)
0: Negative inclination, 1: Positive inclination
0-100 (%)
0
0
800
1
0
Title
Function
Adjustment range
Default setting
PID control waiting time
PID control
Proportional gain
Integral gain
Differential gain
0
0
0.30
0.20
0
Title
Function
Adjustment range
Communication rate
Parity
Inverter number
Communication error trip time
Communication waiting time
Setting of master and slave for
communication between inverters
Communication command point 1 setting
Communication command point 1 frequency
Communication command point 2 setting
Communication command point 2 frequency
Selection of communication protocol
Block write data 1
Block write data 2
Block read data 1
Block read data 2
Block read data 3
Block read data 4
Block read data 5
0, 1, 2, 3, 4
0, 1, 2
0-255
0: Invalid, 1-100 (s)
0-2 (s)
0, 1, 2, 3, 4
0-100 (%)
0.0-500.0 (Hz)
0-100 (%)
0.0-500.0 (Hz)
0, 1
0-5
0-5
0-10
0-10
0-10
0-10
0-10
3
1
0
0
0.00
0
0
0.0
100
60.0
0
0
0
0
0
0
0
0
Default setting
Title
Function
Adjustment range
Default setting
Stall prevention release mode
Small current detection current hysteresis
Small current trip/alarm selection
Small current detection current
Small current detection time
Detection of output short-circuit during start-up
Over-torque trip/alarm selection
Over-torque detection level
Over-torque detection time
Over-torque detection level hysteresis
Cumulative operation time alarm setting
Over-voltage stall protection level
Undervoltage trip/alarm selection
Trip at VIA low level input mode
Annual average ambient temperature
(parts replacement alarms)
0, 1
1-20
0: Alarm only, 1: Tripping
0-100 (%)
0-255 (s)
0, 1, 2, 3
0: Alarm only, 1: Tripping
0-250 (%)
0-10 (s)
0-100 (%)
0-999.9
100-150 (%)
0, 1, 2
0: Invalid, 1-100 (%)
1, 2, 3, 4, 5, 6
0
10
0
0
0
0
0
150
0.5
10
610
*1
0
0
3
Title
Function
Adjustment range
Default setting
Prohibition of parameter change
Prohibition of frequency setting on the operation panel ( )
Panel operation prohibition (RUN/STOP keys)
Prohibition of panel emergency stop operation
Prohibition of panel reset operation
Prohibition of
/ / change
during operation
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0
0
0
0
0
1
External connection input up/down setting parameters
Input from external contacts- UP response time
Input from external contacts- UP frequency step width
Input from external contacts- DOWN response time
Input from external contacts- DOWN frequency step width
Initial value of UP/DOWN frequency
Saving of changed value of UP/DOWN frequency
0.0-10.0 (s)
0.0- (Hz)
0.0-10.0 (s)
0.0- (Hz)
(Hz)
0, 1
0.1
0.1
0.1
0.1
0.0
1
Torque up detailed setting parameter
Title
Function
Adjustment range
Default setting
Exciting current coefficient
Stall prevention control coefficient 1
Stall prevention control coefficient 2
Motor adjustment coefficient
Maximum voltage adjustment coefficient
Waveform switching adjustment coefficient
Starting current suppression function
100-130 (%)
10-250
50-150
0-200
90-120 (%)
0.1-14.0 (kHz)
0: Invalid, 1: Valid
100
100
100
* 1
104
0.2
0
Title
Function
Adjustment range
Default setting
11
Parameters for setting functions that cannot be fulfilled by basic parameters.
■
Output terminal functions list
Function No.
Function
Frequency lower limit
Frequency upper limit
Low-speed detection signal
completion of acceleration/deceleration signal
Designated frequency attainment signal
Failure signal (trip output)
Over-torque detection
Start/Stop
OL pre-alarm
Braking resistor overload pre-alarm
Over-torque detection pre-alarm
pre-alarm
Small-current detection
Significant failure
Insignificant failure
0/1
2/3
4/5
6/7
8/9
10/11
12/13
14/15
16/17
18/19
20/21
22/23
24/25
26/27
28/29
Function No.
Function
Ready for operation (including ST/RUN)
Ready for operation (excluding ST/RUN)
Frequency VIB selection
Fault signal (put out also at the time of a retry)
Specified data output
Specified data output 2
Cumulative operation time alarm
Parts replacement alarm
Braking sequence output
F terminal input signal
Inversion of R terminal input signal
Signal in accordance of frequency command
Undervoltage detection
Invalid settings, always OFF (ignored)
Always OFF
Always ON
30/31
32/33
34/35
36/37
38/39
40/41
42/43
44/45
46/47
48/49
50/51
52/53
54/55
56-253
254
255
Note) For functions 0 to 55, even numbers are true logic and odd numbers are false logic.
Set parameters related to deep carrier frequency motor noise.
Carrier frequency parameters
Set characteristics if input frequency instruction is input from terminal block.
Frequency command (terminal block) specialized parameters
Set protection operations, trip output and alarm output settings etc.
Set specific values for functions such as low-speed/signal output and speed arrival signal output.
Input/output terminal function parameters
A variety of functions can be given to various compatible output terminals by assigning the function
numbers for the parameter in the table below.
Output terminal functions assignment parameters
Protection parameters
Set to generate high torque to match load or motor.
Torque up parameters
Set if changing units displayed or various display methods.
Panel display parameters
List of parameters
12
DC Braking parameters
Title
Function
Adjustment range
Default setting
DC braking starting frequency
DC braking current
DC braking time
Motor shaft fixing control
0.0- (Hz)
0-100 (%/A)
0.0-20.0 (s)
0: Invalid, 1: Valid (after DC braking)
0.0
50
1.0
0
Multi-stage speed run parameters
Power generation braking parameters
Jog run parameters
No. 2 and no. 3 acceleration/deceleration time setting parameters
No. 2 motor parameters
Jump frequency parameters
Forward/reverse/start frequency parameters
Analog/pulse train output setting parameters
Communications functions parameters
Panel settings parameters
PID control setting parameters
Others/option settings parameters
Title
Function
Adjustment range
Default setting
Droop gain
Droop insensitive torque band
Braking mode selection
Release frequency
Release time
Creeping frequency
Creeping time
Free notes
Parameter for option 1
Parameter for option 2
Parameter for option 3
Parameter for option 4
Parameter for option 5
Step-out detection current level
Step-out detection time
High-speed torque adjustment coefficient
0-100 (%)
0-100 (%)
0, 1, 2, 3
-20.0 (Hz)
0.00-2.50 (s)
-20.0 (Hz)
0.00-2.50 (s)
0-65535
0-65535
0-65535
0-65535
0-65535
0-65535
10-150 (%/A)
0.0: Invalid, 0.1-25.0 (s)
0.00-650.0
0
10
0
3.0
0.05
3.0
0.10
0
0
0
0
0
0
100
0.0
0.00
Parameters for setting higher functions.
Extended parameters
2
Detailed protection settings parameters
2005 Ver.112/113
■
input terminal functions list
Extended parameters
1
2005 Ver.112/113
Title
Function
Adjustment range
Always active function selection 1
Always-active function selection 2
Input terminal selection 1 (F)
Input terminal selection 2 (R)
Input terminal selection 3 (RES)
Input terminal selection 4 (S1)
Input terminal selection 5 (S2)
Input terminal selection 6 (S3)
Input terminal selection 7 (VIB)
Input terminal selection 8 (VIA)
0-75 (No function)
0-75 (ST)
0-75 (F)
0-75 (R)
0-75 (RES)
0-75 (SS1)
0-75 (SS2)
0-75 (SS3)
5-17 (SS4)
5-17 (AD2)
0
1
2
3
10
6
7
8
9
5
Default setting
A variety of functions can be given to various compatible input terminals by assigning the function numbers
for the parameter in the table below.
Input terminal functions assignment parameters
Function
No.
Function
No.
Function
No function
Standby
Forward run command
Reverse run command
Jog run mode
Acceleration/deceleration 2 pattern selection
Preset-speed command 1
Preset-speed command 2
Preset-speed command 3
Preset-speed command 4
Reset command
Trip stop command from external input device
Switching of command mode and frequency setting mode
DC braking command
PID control prohibited
Permission of parameter editing
Combination of No. 1 and 10
Combination of No. 1 and 12
Combination of No. 2 and 4
Combination of No. 3 and 4
Combination of No. 2 and 5
Combination of No. 3 and 5
Combination of No. 2 and 6
Combination of No. 3 and 6
Combination of No. 2 and 7
Combination of No. 3 and 7
Combination of No. 2 and 8
Combination of No. 3 and 8
Combination of No. 2 and 9
Combination of No. 3 and 9
Combination of No. 2, 5 and 6
Combination of No. 3, 5 and 6
Combination of No. 2, 5 and 7
Combination of No. 3, 5 and 7
Combination of No. 2, 5 and 8
Combination of No. 3, 5 and 8
Combination of No. 2, 5 and 9
Combination of No. 3, 5 and 9
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Function
Frequency command forced switching
No.2 Switching of V/F setting
Combination of No. 5, 39 and 61
Frequency UP signal input from external contacts
Frequency DOWN signal input from external contacts
Frequency UP/DOWN cancellation signal input from external contacts
Combination of No. 10 and 43
Inversion of No. 11
Thermal trip stop signal input from external device
Inversion of No. 46
Forced switching from remote to local control
Operation holding (stop of 3-wire operation)
Forced switching of command mode and terminal board command
Display cancellation of the cumulative power amount (kWh)
Forced operation (factory configuration required)
Fire-speed control
Coast stop (gate off)
Inversion of No. 10
Combination of No. 1 and 2
Combination of No. 1 and 3
Acceleration/deceleration 3 selection
Combination of No. 2 and 58
Combination of No. 3 and 58
Forced switching of stall prevention level 2
Holding of RY-RC terminal output
Holding of OUT-NO terminal output
Cancellation (clearing) of operation command from panel
PID control integral value clear
Combination of No. 1, 2 and 6
Combination of No. 1, 3 and 6
Combination of No. 1, 2 and 7
Combination of No. 1, 3 and 7
Combination of No. 1, 2 and 8
Combination of No. 1, 3 and 8
Combination of No. 1, 2 and 9
Combination of No. 1, 3 and 9
Combination of No. 1, 2 and 4
Combination of No. 1, 3 and 4
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Output terminal selection 1A (RY-RC)
Output terminal selection 2A (OUT-NO)
Output terminal selection 3 (FL)
Output terminal selection 1B (RY-RC)
Output terminal selection 2B (OUT-NO)
Output terminal logic selection (RY-RC, OUT-NO)
0-255 (LOW)
0-255 (RCH)
0-255 (FL)
0-255 (always ON)
0-255 (always ON)
0, 1, 2, 3
4
6
10
255
255
0
Title
Function
Adjustment range
Default setting
Title
Function
Adjustment range
PWM carrier frequency
Random mode
Carrier frequency control mode selection
2.0-16.0 (kHz)
0: Invalid, 1: Automatic setting
0, 1, 2, 3
12.0
0
1
Default setting
Title
Function
Adjustment range
Frequency priority selection
VIA input point 1 setting
VIA input point 1 frequency
VIA input point 2 setting
VIA input point 2 frequency
Frequency setting mode selection 2
VIB input point 1 setting
VIB input point 1 frequency
VIB input point 2 setting
VIB input point 2 frequency
VIA input bias
VIA input gain
VIB input bias
VIB input gain
0
,
1
0
-
100 (%)
0
-
500 (Hz)
0
-
100 (%)
0
-
500 (Hz)
0
-
6 (same as )
0
-
100 (%)
0
-
500 (Hz)
0
-
100 (%)
0
-
500 (Hz)
-
-
-
-
0
0
0.0
100
50 (WP)
60 (WN)
1
0
0.0
100
50 (WP)
60 (WN)
-
-
-
-
Default setting
Title
Function
Adjustment range
Default setting
Low-speed signal output frequency
Speed reach setting frequency
Speed reach detection band
Analog/logic input function selection
(VIA/VIB terminal)
Frequency command agreement
detection range
0.0
0.0
2.5
0
2.5
0
-
(Hz)
0
-
(Hz)
0
-
(Hz)
0
-
4
0
-
(Hz)
Title
Function
Adjustment range
Default setting
Auto-restart control selection
Regenerative power ride-through control (Deceleration stop)
Retry selection (number of times)
Overvoltage limit operation (Slowdown stop mode selection)
Supply voltage correction (limitation of output voltage)
Stall prevention level 1
Inverter trip retention selection
Emergency stop selection
Emergency DC braking time
Output phase failure detection mode selection
Motor 150%-overload time limit
Input phase failure detection mode selection
0
0
0
2
3
150
0
0
1.0
0
300
1
0, 1, 2, 3, 4
0,1, 2
0: Invalid, 1-10 (times)
0, 1, 2, 3
0, 1, 2, 3
10-199 (%/A), 200 (Invalid)
0, 1
0, 1, 2
0
-
20 (s)
0, 1, 2, 3, 4, 5
10-2400 (s)
0: Invalid, 1: Valid
Title
Function
Adjustment range
Auto-tuning
Slip frequency gain
Automatic torque boost value
Motor rated current
Motor no-load current
Motor rated speed
Speed control response coefficient
Speed control stability coefficient
0
50
* 1
* 1
* 1
1710
40
20
0, 1, 2
0-150 (%)
0-30 (%)
0.1-100.0 (A)
10-90 (%)
100-32000 (min-1)
1-150
1-100
Default setting
* 1: Default values vary depending on the capacity.
Title
Function
Adjustment range
Default setting
Unit selection
Free unit selection
Inclination characteristic
of free unit display
Free unit display bias
Free step 1 (pressing a panel key once)
Free step 2 (panel display)
Standard monitor display selection
Canceling of operation command
when standby terminal (ST) is turned off
Panel stop pattern
0
0.00
1
0.00
0.00
0
0
1
0
0: %, 1: A (ampere)/V (volt)
0.00: Invalid, 0.01-200.0
0: Negative inclination,
1: Positive inclination
0- (Hz)
0.00: Invalid, 0.01- (Hz)
0: Invalid, 1-255
0,1,2,3,4,5,6,7
0: Operation command canceled (cleared),
1: Operation command retained
0: Slowdown stop, 1: Coast stop